User Manual

TII P/N: 92202701
4.1 STATION PROTECTOR WIRING
(If equipped with binding post protection)
a) Connect the drop wire to the Tip and Ring of the
protector module, placing the wire under the bottom
nut on each stud for station protector module (See
Figure 2).
b) Turn the cover assembly over and locate the spade
tipped red and green conductors that are attached to
the modular jack. Connect them to the Ring and Tip
binding posts of the protector module respectively.
c) Inspect the ground wire and drop wire connections.
d) See 4.2 3 Final Installation Steps
4.2 STATION PROTECTOR WIRING
(If equipped with angle driver)
4.2.1 Upper Port Subscriber Connections
a) Turn the cover assembly over and Cut spade lugs from
Red and Green conductors that are attached to the
modular jack.
b) Do not strip wire insulation. Make certain wire ends
are cut flush with insulation.
c) Unscrew Angle Driver screw to full upright position.
d) Fully insert the two wires into their respective Tip and
Ring (color-coded) ports.
e) While holding the two Customer side wires in place
tighten Drive Screw to full down position.
4.2.2 Lower Port Telco Connections
a) Do not strip wire insulation. Make certain wire ends
are cut flush with insulation.
b) Unscrew Angle Driver screw to full upright position.
c) Fully insert the two wires into their respective Tip and
Ring (color-coded) ports.
d) While holding the two Telco wires in place tighten
Drive Screw to full down position.
e) See 4.2.3 Final Installation Steps.
4.2.3 Final Installation Steps
a) Locate the yellow and black conductors also
attached to the modular jack and insulate them with
a short piece of tape. Dress them to the side so as
not to interfere with the working of the unit. (The
yellow and black wires may also be terminated on
the protector ground post if desired.)
b) Carefully fit the cover assembly onto the base of
the protector, ensuring that no loose ends or other
wire pieces are protruding between the cover and
base.
c) Locate the ground stud with the nylon nut of the
cover and screw it down until the cover is fitted
snugly to the base.
d) Carefully place the station wire in the lip of the
grommet and terminate the conductors on the
customer wiring bridge. Inspect for shorts and
broken wires.
e) Insert the modular plug into the modular jack and
close the hinged door.
4. INSTALLATION WITH STATION ELECTRONICS
a) Follow steps 4a -4e then proceed to next step.
b) Terminate the Tip-in and Ring-in leads of the
electronics assembly onto the protector module
binding posts or angle driver termination, and
ground stud if required.
c) Take a short piece of station wire and connect the
red and green conductors respectively to the
Ring-out and Tip-out terminals of the station
electronics assembly.
d) Run this wire to the protector or angle driver and
dress the end into the protector. Remove a portion
of the jacket and prepare the red and green
conductors to be spliced to the spade tipped red
and green conductors of the cover assembly of the
unit.
e) Locate the red and green spade tipped conductors
attached to the modular jack and cut off the spade
tips.
f) Using a Scotch-Loc or B wire connector, or some
other splicing device, splice the red conductor from
the Ring-out of the electronics assembly to the red
conductor attached to the modular jack. Splice the
green conductor from the Tip-out of the electronics
assembly to the green conductor attached to the
modular jack.
g) Dress all loops and extra conductors neatly inside
the protector and carefully fit the cover assembly
onto the base of the protector. (The yellow and
black wires from the modular jack may be insulated
and taped back, or terminated on the protector
ground post.)
h) Complete installation by following steps 4.2.3 (c-e).
Figure 2
Customer Side Cable
Telco Side Cable
Telco Side Cable
Customer Side Cable
Angle Driver Screw