User Manual

141 Rodeo Drive tii 3800 Series
Edgewood, NY 11717 COCOT Mounting Base
Toll Free 888.844.4720 tii P/N: 92213401
www.tiinettech.com 01/08 Rev E
INSTALLATION NOTE
1. GENERAL
The tii 3800 Series COCOT (Customer Owned Coin
Operated Telephone) provides a demarcation point
between the telephone service provider network and
the subscriber’s telephone wires. The Network
Interface Device (NID) may contain gel sealed station
protectors (tii Angle Drivers), or other primary station
protectors such as tii’s 355, 356, 127, etc., and sealed
subscriber bridges (tii 95S Series). These primary
surge protection modules provide primary electrical
protection for subscribers. The tii 95S Series provides
subscriber connections and a demarcation test
access point. Each can terminate up to four
subscriber extension line connections which will
automatically disconnect when the customer uses the
RJ-11 port for testing.
NOTE: See separate installation note if the unit is
equipped with tii 95S Series ADSL POTS Splitter module.
Each Angle Driver module can connect one pair of 18-
24 AWG (1.02-0.51mm) central office (c.o.) wire and
one pair of 22-24 AWG (0.65-0.4mm) subscriber
bridge wires. Connections are created with insulation
displacement connection (IDC) blades and are
environmentally sealed.
The NID housing is constructed from rugged, heat and
solvent resistant, UV stabilized materials.
CAUTIONS AND WARNINGS
Use company-approved safety practices and
equipment.
Only solid conductors can be used for connecting to
the Angel Driver and the tii 95S Series Subscriber
Bridges; Do Not Use Stranded Wire.
Stranded or solid wires can be used on binding post
termination primary protectors.
Do not strip insulation from conductors when
terminating to an IDC connector.
If the hook up wire, OSP wire, or central office cable
is physically larger than 22 AWG, a fusing conductor
of 22 AWG or smaller solid copper wire with
thermoplastic insulation must be used. Install the
fuse link per local practices and approval agencies.
This installation note may be used for binding post
terminating primary protectors
2. INSTALLATION
The 3800 COCOT NID Series is equipped for screw
fastener mounting.
Figure 1

Summary of content (2 pages)