Cat No. MLB500C - Black Cat No. MLW500C - White 150W multi Pir Halogen floodlight Cat No. MLB150C - Black Cat No.
SECTION ONE GENERAL INFORMATION The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the lamp will illuminate for a user-determined time period. An integral daylight sensor ensures night-only operation. PARTS INCLUDED - Luminaire c/w PIR Sensor unit. - Instruction manual. Please keep safe for future reference. - Accessory Pack. - Tungsten halogen bulb TOOLS & PARTS NEEDED - Electric/hand-held drill & bits.
SECTION THREE INSTALLATION *** IMPORTANT *** Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. After choosing a suitable location (see previous section) install the unit as follows: Remove the wiring box cover by unscrewing the retaining screw (fig F) and with a screwdriver gently push down and ease out. The unit is suitable for connection to a 230 V ac 50Hz electricity supply.
Place this edge against walland use diagram to estimate incoming cable length 75mm (3”) NOT TO SCALE 25mm (1”) INCOMING WIRE TEMPLATE Use this diagram to estimate incoming cable length
E G Time Dusk/Dawn Holiday Mode F H Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection
CONNECTION DIAGRAM Mains Supply Isolation Switch The diagram below also shows the required connections for the addition of slave luminaires. When adding slaves, be sure not to exceed the maximum switchable load (see Technical Specifications). SECTION FOUR OPERATION AND TESTING WALK TEST PROCEDURE The sensor will rotate from left to right, and tilt forward or backward. Adjust the sensor to point in the required direction. (note diagram B) The unit can be set up in daylight or at night.
TOP VIEW A 200º C SIDE VIEW 2.
Manual Override Mode is indicated by the permanent illumination of a single red LED in the top of the sensor head. To switch the unit back into Auto Mode, flick the internal wall switch/circuit breaker off/on once within 1 second. The unit will return to Auto Mode. This is indicated by the return of the left to right scrolling LED's as described in Automatic Operation above.
TEST MODE - THREE LEDS VISIBLE The lamp will now illuminate for approximately 2 seconds every time movement is detected. Walk across the detection area approximately 5 metres from the unit. Each time you are detected the lamp will illuminate. Now stand still until the lamp extinguishes (this should take approx. 2 seconds) Start moving again, when you are detected again the lamp will illuminate. Repeat the above, walking at various angles and distances to the unit.
In the event of the cover glass shattering, do not replace with normal household glass. Contact the Timeguard helpline for replacement details. *The lamp supplied is a class C (high efficiency) unit of 400W power consumption giving a similar light output to the lower efficiency 500W units previously in use. **The lamp supplied is a class C (high efficiency) unit of 100W power consumption giving a similar light output to the lower efficiency 150W units previously in use.
PROBLEM SOLUTION o PIR sensor will not operate at all. Check that the power is switched ON at the circuit breaker/ internal wall switch. Turn OFF the power to the unit and check the wiring connections as per the diagram (see previous section 3). Ensure no connections are loose. Check the lamp. If the lamp has failed, replace. Ensure that the lamp is seated correctly in the lampholder. o The PIR sensor will not operate at night.
For assistance with the product please contact:- Helpline 020-8450-0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND Tel: 020-8452-1112 or email csc@timeguard.com A Group company 67-058-310 (Iss.