Model: MLBPRO500C (Black) Model: MLWPRO500C (White) Installation & Operating Instructions 500W “C” Class Halogen Floodlight with 240º PIR Control
1 Introduction Thank you for choosing the MLB/WPRO500C. It is our new generation of sensor light technology, providing benefits in better performance and a quick and easy installation compared with other sensor lights on the market. It is integrated with years of experience and broad expertise in manufacturing sensor detectors and sensor lights for professional use. The MLB/WPRO500C has the following outstanding features and superior functions that will meet most of your needs.
PIR Coverage 4 Installation The MLB/WPRO500C should be installed within the height range 2.0m to 2.5m. (See Fig. 2). Installation shouild only be carried out by a competent person. The unit has an adjustable lens with two detection zones. • The outer zone covers an angle of 240º to a distance of approx. 3m to 16m at an installation height of 2.3m. (See Fig. 3). • The inner zone covers an angle of 360º which allows detection immediately behind the MLB/WPRO500C. (See Fig.4).
Front Glass Fig. 8 Backplate 1 m Min. d. Install bulb: 1. Remove the lamp cover screws retaining front glass frame (See Fig. 9) and swing the glass frame away from the floodlight cover. 2. Check that the bulb and fitting contacts are all clean, ensuring that you hold the bulb with a clean dry cloth during this and subsequent procedures. Fig. 11 Switch terminal L N L L1 3.
B Installation of Corner Mounting Adapter (Option) D The Adjustments of MLB/WPRO500C: a. Make hole(s) in the wall plate as required and insert grommets. b. Make hole(s) if any in the corner mounting adapter (none will be required if only the bottom entry hole(s) are in use on the backplate). c. Fix the backplate to the corner mounting adapter using the 3 large pan head screws supplied (used to fix the backplate to the wall when the adapter is not in use). d.
5 Function and Operation A Lens Shield - function The lens shield contains 13 segments each of which can be broken in half. Each segment can block 10º detection angle within the field of view by pressing it onto the outer ring of the sensor head. (See Fig. 25). The segments only work on the outer 240º zone. The inner 3m radius zone is unaffected. • How to use: 1. Take the outer ring off the sensor head. (See Fig. 24). 2. Decide on the detecting zone (or zones) that you want to be reduced or blocked. Fig.
C Setting of LUX, METER and TIME Knobs for Automatic Operation (See Fig. 27). 11 When Walk Tests are complete, the unit can be set up for Automatic mode. The TIME setting controls how long the unit remains illuminated following activation and after all motion ceases. The minimum time (fully anti-clockwise) is approx. 6 seconds, whilst the maximum time (fully clockwise) is approx. 12 minutes. Set the control to the desired setting between these limits.
7 Technical Specifications Input Voltage: 230V ~ 50Hz. Load: 400W class C halogen light plus additional loads, three 400W class C halogen lights or fluorescent loads up to 200W can be connected. Power Consumption: Less than 1W.
HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com Zerofour – June 2010 Designed in the U.K. 67-058-351 ISS.