Cat No. NSLB500C - Black Cat No. NSLW500C - White 150W PIR HALOGEN FLOODLIGHT Cat No. NSLB150C - Black Cat No.
12m 5sec 5min NSLB500C/NSLW500C ADJUSTABle ADJUSTABle ADJUSTABle 500W PIR Halogen Floodlight M WeATHeRpROOF MAnUAl OVeRRiDe 70 ip55 CliCK OnCe Ge F x1 pRODUCT Black 1 p 2 500w COlOUR MAXiMUM eleCTRiCAl piR SWiTCHinG 2300w lAMp TYpe piR SWiTCHinG DeTeCTiOn AnGle DeTeCTiOn RAnGe DeTeCTiOn AnGle DeTeCTiOn RAnGe 2300w TiMe On DUSK TO DAWn 500w MAXiMUM 180º MAXiMUM 12m 180º 12m 5sec MAnUAl OVeRRiDe ADJUSTABle DiMenSiOnS - MM ADJUSTABle WeATHeRpROOF inSTAllATiOn DiMenSiOnS
12m 5sec 5min NSLB150C/NSLW150C ADJUSTABle ADJUSTABle ADJUSTABle 150W PIR Halogen Floodlight M WeATHeRpROOF MAnUAl OVeRRiDe 70 ip55 CliCK OnCe Ge F x1 Black 1 2 150w MAXiMUM COlOUR eleCTRiCAl piR SWiTCHinG 2300w lAMp TYpe piR SWiTCHinG DeTeCTiOn AnGle DeTeCTiOn RAnGe DeTeCTiOn AnGle DeTeCTiOn RAnGe 2300w TiMe On DUSK TO DAWn 500w MAXiMUM 180º MAXiMUM 12m 180º 12m 5sec MAnUAl OVeRRiDe ADJUSTABle DiMenSiOnS - MM ADJUSTABle WeATHeRpROOF inSTAllATiOn DiMenSiOnS - MM WeATHe
SECTION ONE GENERAL INFORMATION The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the lamp will illuminate for a user-determined time period. An integral daylight sensor ensures night-only operation if required. PARTS INCLUDED - Luminaire c/w PIR Sensor unit. - Instruction manual. Please keep safe for future reference. - Accessory Pack. - Tungsten halogen bulb. TOOLS & PARTS NEEDED - Electric/hand-held drill & bits.
E SECTION THREE INSTALLATION Retaining Lugs After choosing a suitable location (see previous section) install the unit as follows: Mounting Plate/ Wiring Box Insert small screwdriver and gently push and lift cover off. Remove the wiring box cover by gently levering the side retaining lugs outwards and lift off (see diagram E). The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that 3-core round flexible cable of 1mm2 gauge is used.
F CONNECTION DIAGRAM Mains Supply Isolation Switch External Wiring The diagram below also shows the required connections for the addition of slave luminaires. When adding slaves, be sure not to exceed the maximum switchable load (see Technical Specifications).
SECTION FOUR commissioning and operation WALK TEST PROCEDURE The sensor will rotate from left to right, and tilt forward or backward. Adjust the sensor to point in the required direction and angle down to limit forward range as required. The unit can be set up in daylight or at night. Set the time adjustment to minimum(fully anti-clockwise) and the light threshold to maximum (fully clockwise) see diagram C. Turn the power to the unit on. The lamp will illuminate for approximately 30 seconds.
A TOP VIEW 180º Light Level Sensor Dusk Level Adjust C Delay Time Adjust SIDE VIEW 2.5m BOTTOM VIEW 12m B Lens Mask D Less sensitive Restrict long detection Restrict short detection More sensitive Restrict RHS detection Restrict LHS detection MASKING THE SENSOR LENS To restrict the sensor coverage, preventing detection in unwanted areas, mask the sensor lens using the masking label provided (see diagram D). The top section of the lens covers long range detection, the bottom covers short range.
SECTION SIX TROUBLESHOOTING GUIDE PROBLEM SOLUTION ❏ Lamp stays ON all the time night and day. Check wiring connections. Wires to L and L1 terminals may be transposed. ❏ Lamp stays ON all the time at night, or PIR keeps activating at random for no apparrent reason. The unit may be suffering from false activation. Cover the sensor lens completely with black pvc tape. This will prevent the sensor from "seeing" anything.
SECTION FIVE TECHNICAL SPECIFICATIONS Detection Range Up to 12 metres Detection Angle Power Supply 180º 230 V AC ~ 50Hz Maximum External Load NSLB/W150C 2150W Halogen/Incandescent 375W any fluorescent system (including LE) NSLB/W500C 1800W Halogen/Incandescent 375W any fluorescent system (including LE) Fitted Lamp Type NSLB/W150C 230V Linear Tungsten Halogen 100W type C max (R7S cap)* NSLB/W500C 230V Linear Tungsten Halogen 400W type C max (R7S cap)** Time On Adjustment 5 seconds -
For assistance with the product please contact:- Helpline 020-8450-0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND Tel: 020-8452-1112 or email csc@timeguard.com A Group company 67-058-302 (Iss.