Cat Nos.
RTS113/RTS113Q/RTS114/RTS114Q Round Pattern Electromechanical Timeswitches 7 day control (blue) 24 hour control (Red) Permanent ON override push button 7 day programming ring (divided into 12 hour steps) Blue tappet (OFF) Time marker Permanent override indicator AM segment PM segment 1 24 hour programme ring Red tappet (ON) Terminal cover 1.0 Description: 1.
1.3 Technical Data 2 Type: RTS113/RTS113Q/RTS114/RTS114Q Type of programme: Daily with half day(s) and day(s) omitted over a 7 day period if required Operating voltage: 220-240V AC 50Hz *Switching capacity: 20A, 240V~ for resistive loads Contact material: Hard silver Type of contact: ON/OFF mains linked RTS113/RTS113Q, voltage free RTS114/RTS114Q Time base: Quartz Operating accuracy: ≤ ± 1 sec./day at 23°C Min. switching interval: 30 min, which can be increased in 15 minute steps. Max.
2.0 Installation Instructions: 2.1 Safety Information The RTS113/RTS113Q/RTS114/RTS114Q should only be installed by a trained electrician. The I.E.E. wiring regulations must be observed. The supply must be disconnected before wiring commences and a means of isolation with a separation of 3mm in each current path must be provided in the supply to the RTS unit. This product must not be installed where it may come into direct contact with liquids. The RTS unit is suitable for fixed wiring applications only.
Remove the transparent cover from the RTS unit by rotating it anticlockwise through 30° and then pulling it clear. Unscrew the screw A (see fig. 3), remove the terminal cover and pull the timeswitch plug-in assembly clear of the base. Drill out the three fixing screw holes in the base (see fig. 2) and use 3 x No. 8 woodscrews (with wall plugs if necessary) to fix the RTS unit to the mounting surface. Alternatively the unit may be fixed to panelling using 2B.A.
7 day output control (blue) OFF at 1200 (blue tappet) 24 hour output control (red) ON at 0900 (red tappet) Time marker AM marker bar Permanent override indicator ON at 2000 (red tappet) Segment set to change 7 day output OFF at 2200 (blue tappet) Fig 5 3.2 Half day and day omit programming and 7 day control setting. 5 This is required only if the programme set on the 24 hour ring is not needed for one or more half days.
3.5 Programming Overview Time marker 7 day output control (blue) Clockwise direction for 24 hour and 7 day rings 24 hour control (red) Sunday markers (in red) Red tappet Blue tappet 7 day ring 2 segments set to give changes to 7 day control at midday Thursday and midnight Thursday. With 7 day control set at ■ (ON) above no 24 hour operation will occur between midday and midnight each Thursday.
For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: 67-058-78 (issue 3). Zerofour – November 2013 Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.