SDS

Page 5 of 11 Report No.: TWE2403008-001
Section 4.
First aid measures
Ingestion: Give at least 2 glasses of milk or water. Induce vomiting unless patient is unconscio
us. Call a physician
Inhalation: Remove from exposure and move to fresh air immediately. Use oxygen if available.
Eye: Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and
lower eyelids. Get medical aid.
Skin: Remove contaminated clothes and rinse skin with plenty of water or shower for 15
minutes, Get medical aid.
Section 5.
Fire-fighting measures
Flash Point: N/A.
Auto-Ignition Temperature: N/A.
Extinguishing Media: lots of water, CO2
Special Fire-Fighting Procedures: Self-contained breathing apparatus.
Unusual Fire and Explosion Hazards: Cell may vent when subjected to excessive
heat-exposing battery contents.
Hazardous Combustion Products: Carbon monoxide, carbon dioxide, lithium oxide fumes.
Section 6.
Accidental release measures
Steps to be taken in case Material is Released or Spilled
If the battery material is released, remove personnel from area until fumes dissipate. Provide
maximum ventilation to clear out hazardous gases. Wipe it up with a cloth, and dispose of it in a
plastic bag and put into a steel can. The preferred response is to leave the area and allow the
battery to cool and vapors to dissipate. Provide maximum ventilation. Avoid skin and eye
contact or inhalation of vapors. Remove spilled liquid with absorbent and contain for disposal.