Warranty
Application Guidelines
Application Temperature Over 50°F. for adhesive and substrates
Service Temperature Range 0°F. to 120°F.
Method of Application Mason’s trowel
Working Surfaces Surfaces must be dry and free from any material that may deter adhesion. Using the "butter"
method, spread a thin layer of adhesive to cover a large area of each corner of the tile. Then apply adhesive in 1"to
1 1/2"mounds (golf ball size). Place mounds 2-3 inches in from the corners on the back of the tile. Immediately
press tile into position, working the tile back and forth 1/2" to flatten the mounds of adhesive. Adhesive must be
flattened to a mound 3/16" to 3/8" thick and 2 1/2" in diameter. When installing interlocking tile, do not slide tile into
groove of adjacent tile until it has been positioned to its proper level.
Cleanup Tools and excess adhesive may be cleaned with water while the adhesive is wet. If dried, tools and
adhesive may be cleaned with mineral spirits or equivalent solvent. Follow solvent vendor's precautions when
using solvents. NOTE: Test solvent on an out-of-the-way area to make sure it will not mar or attack the surface.
Coverage 50-60 sq. ft. of ceiling tile per gallon.
Limitations
Not recommended for use on tiles larger than 12" x 12". For best results, store Titebond Solvent Free Acoustical
Ceiling Tile Adhesive above 50°F. Do not store product outside if temperature is below 50°F. Product must be
stored inside a climate controlled area that is above 50°F. For further questions about applications that are not
covered here, please call Tech Service at 1-800-347-GLUE (4583).
Caution Statements
CAUTION: EYE AND SKIN IRRITANT. Contains propylene glycol. Do not swallow. Do not allow eye contact or
prolonged skin contact. FIRST AID: If swallowed, do not induce vomiting; contact physician. If eye contact occurs,
flush with water for 15 minutes. Wash skin contact areas with soap and water. If irritation from eye or skin contact
areas persists, contact physician. For additional information, refer to Safety Data Sheet.
KEEP OUT OF THE REACH OF CHILDREN.
Ordering Information
Part No. Size Weight UPC Case UPC Units Per Package Packages Per Pallet
2704 4 Gallon Pail 50.69 037083027044 1 36
2706 Gallon Pail 25.26 037083027068 10037083027065 2 75
Important Notice: Our recommendations, if any, for the use of this product are based on tests believed to be reliable. Since the use
of this product is beyond the control of the manufacturer, no guarantee or warranty, expressed or implied, is made as to such use or
effects incidental to such use, handling or possession or the results to be obtained, whether in accordance with the directions or
claimed so to be. The manufacturer expressly disclaims responsibility therefore. Furthermore, nothing contained herein shall be
construed as a recommendation to use any product in conflict with existing laws and/or patents covering any material or use.
2020 Bruck Street, Columbus, Ohio 43207
CUSTOMER SERVICE 1-800-669-4583
TECH SERVICE 1-800-347-4583
www.titebond.com