Product Manual B

Harbor View Windows, Heating and Air, Inc., Brookings, Oregon, has
installed ductless split system heating/cooling for years. Ductless sys-
tems offer high-energy savings, but can also have comfort challenges if
an air handler is not installed in each room. On a recent multi-family
project using ductless systems, Harbor View was able to overcome this
problem by installing an average of two AireShare transfer fans per
five-room townhouse to effectively distribute conditioned air to rooms
without air handlers.
“We thought it might be a great solution to a long term problem…to
flip a switch and be able to draw air conditioned or heated air out of
the main
rooms into
the small
rooms and
it’s working
perfectly,”
said Pat and
Sherry Nied,
Harbor
View’s
owners.
AireShare
Transfer Fan
Air
Handler
A
C
B
A
B
Floor/Ceiling Grilles
for Model ASLL
AB C
13 3/4” 5 3/4” 1/4”
B
C
A
TJERNLUND PRODUCTS, INC.
1601 Ninth Street White Bear Lake, MN 55110-6794
Phone: 651.426.2993 800.255.4208 Fax: 651.426.9547
Visit our web site: www.tjernlund.com
Copyright © 2014 Tjernlund Products, Inc. All rights reserved. P/N 8500730 Rev C 10/14
Model AS1
Intake Grille
Model AS2
Intake Grille
A
B
Model AS1P
Intake Grille
B
A
C
C
Model Selection Advice:
Since it is impractical to calculate heating and cooling loads for the variety of
geographic areas, construction methods and the temperature of transferred air
we base our model selection advice on providing a minimum of 3 Air
Changes/Hour (A CH) to the target room. Door under- cuts or pressure relief trans-
fer grilles in the target room are necessary for proper AireShare performance .
AS1 & AS1P for rooms up to 150 Ft
2
AS2 for rooms up to 275 Ft
2
ASLL for rooms up to 175 Ft
2
Diffuser for Models
AS1, AS1P & AS2
ABC
15 1/8” 3” 3 7/8”**
Adjustable Sleeve
for Model ASLL
ABC
12 1/4” 8 3/4” to 16 1/2” 4 1/4”
Intake Grille
Dimensions Minimum A* B*
Model A B C Wall Cavity Volts Watts CFM Speed Sones Sones
AS1
AS1P
ASLL
AS2
3”
3”
N/A
4”
120
120
120
120
20
20
20
30
21
16
15 3/4”
16”
13 3/4”
16”
73/4
73/4
53/4
10”
1/4”
1 1/4”
1/4”
2 1/2”
C
B
A
Dimensions and Specifications:
AS1: Room-to-
Room Cross-
flow Fan,
Hardwired
AS1P: Room-to-Room
Cross-flow Fan,
Plug-in (install over
existing outlet)
AS2: Room-to-
Room Dual Inlet
Blower, Hardwired
(wire for desired
speed upon install)
ASLL: Level-to-
Level Cross-flow
Fan, Hardwired
(AireShare CFM x 60) / (L x W x H of target room) = ACH
3-4 Air Changes/hour (ACH) recommended for best temperature equalization.
4-5 Air Changes/hour (ACH) recommended for rooms with high cooling or
heating loads.
Examples: Rooms with extensive outside walls, windows, over tuck under
garages or in extreme climates. More than one AireShare transfer fan can
be installed to reach desired number of air changes for large spaces.
Fixed
Fixed
Fixed
Hi
Med
Low
1.2
1.4
1.2
1.5
1
<1
60
60
70
110
95
80
1
1
1
1
<1
<1
Case History:
AireShare
TM
transfer fans enhance
performance and comfort of split
system air handlers
For more
information
A* Sones: Intake Room
B* Sones: Target Room
Aire hare
TM
TJERNLUND
**Collapses for 2” x 3”
stud compatibility
C