Draft Inducers Spec Sheets

MODEL HD DRAFT INDUCER
SPECIFICATIONS
Performance curves
HD
MODEL
WITHWITH
GAS FIRING
PIPE
CONTROL
BAR. DRAFT
DRAFT HOOD
WITH
IN.
SIZE
CONTROL
BAR. DRAFT
GAS FIRING OIL FIRING
FLUE GASFLUE GAS
INPUT
HEATER
BTU
HEATER
INPUT
BTU
FLUE GAS
INPUT
BTU
HEATER
S.P. CFM S.P. CFM S.P. CFM
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
MOTOR SPECIFICATIONS
ELECTRICAL DATA
Volts 208-230, 460
Hertz 60
RPM 1725
Watts 2 HP
Amps 6.3 @ 208
6.4 @ 230
3.2 @ 460
Therm. Prot. No
1. Inputs shown are believed to be
maximum capacities for inducers when
mounted on pipe sizes shown for
ordinary jobs where a moderate amount
of mechanical induced draft is required.
2. Consideration is given to typically
higher static pressure requirements for
larger installations, for the type of fuel
burned and for the type of draft control
installed.
3. Where pressure requirements are
unknown or believed to be unusually
severe, ask for complete performance
curves or consult factory.
4. All ratings have been developed in our
testing and research department and
have been approved by a nationally
known independent testing laboratory.
Certification is available upon request.
5. Heating capacities shown are for 1000
BTU per cubic foot natural gas and for
139,000 BTU per gallon No. 2 fuel oil.
Consult factory for capacities with other
fuels. Heating capacities are based on
typical combustion efficiencies and
allow for approximately 5 percent
ambient air drawn into inducer to
cool motor and drives.
6. Draft Inducers should be installed
in single wall vent pipe in order
to insure proper performance.
Note: Tjernlund Products, Inc. reserves the
right to make changes to specifications without
notification.
Static pressure inches H20 (70
o
F Air)
Static pressures shown are “negative” and apply only on inlet side