3. INSTALLATION
3.1 AC Mains Supply.
The unit is fitted with an internationally approved 3 pin IEC connector. A
mating socket with power cord is provided with the unit, wired as follows:
Brown: Live.
Blue: Neutral.
Green/Yellow: Earth (Ground).
All mains wiring should be performed by a qualified electrician with all power
switched off, and the earth connection must be used.
Before connecting the unit to the supply, check that the unit is set for the
correct mains voltage. The unit is internally set for 110-120V 60Hz or 220-
240V 50Hz operation, and should only be changed by an authorised service
centre. The mains fuse required is 20mm anti-surge, 1AT rated at 250V. If it
ever necessary to replace the fuse, only the same type and rating must be
used. The power consumption of the equipment is 20VA.
Warning: attempted operation on the wrong voltage setting, or with an
incorrect fuse, will invalidate the warranty.
3.2 Audio Operating Level.
The 5001 is equipped with outputs suitable for connection to a wide variety of
other audio equipment. Generally, the balanced XLR connections will be
required for interfacing to other professional equipment, where the operating
level (line-up level or nominal level) will be +4dBu, or about 1.2V rms. The