User Manual

12
7. MUTING FUNCTION
7.1. Manual Mute
Step 1. Set the inputs to be muted (Mute Receive inputs) with the Function switch B.
Shift the DIP switches 1 to 5 to ON position to place each corresponding input in Mute Receive
(muted) mode as follows.
• DIP switch 1: MIC input
• DIP switch 2: LINE 1/TEL input
• DIP switch 3: LINE 2 input
• DIP switch 4: LINE 3 input
• DIP switch 5: MODULE input
Note
Avoid assigning both Mute Receive and Mute Send functions to the same input.
Step 2. Close between the Manual mute (+) and (–) terminals.
The Inputs set for Mute Receive in Step 1 are muted.
Step 3. Open between these terminals.
The signal being muted returns gradually to its original level in about 1 to 5 seconds.
Note: This function is active regardless of the Automatic mute ON/OFF setting using the Function switch A.
Manual mute and Automatic mute are available for the muting function.
Manual mute is a function to mute the MIC, LINE 1/TEL, LINE 2, LINE 3 and/or MODULE input placed in Mute
Receive mode when the manual mute terminal is short-circuited.
Automatic mute is an audio-signal activated muting function to automatically mute the MIC, LINE 1/TEL, LINE
2, LINE 3 and/or MODULE input placed in Mute Receive mode when audio signals enter the MIC, LINE
1/TEL, or MODULE input placed in Mute Send mode.
Neither manual mute nor Automatic mute works on the MOH output.
Function switch A
Function switch B