INSTALLATION MANUAL DIGITAL MIXER D-2000 Series (Version 4) D-2008SP D-2012C/ 2012AS Thank you for purchasing TOA's Digital Mixer. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
TABLE OF CONTENTS 1. HANDLING PRECAUTIONS ........................................................................... 5 2. NOMENCLATURE AND FUNCTIONS 2.1. D-2008SP Digital Mixing Processor Unit ............................................................ 6 2.2. D-2012C Remote Console Unit ........................................................................ 10 2.3. D-911 VCA Fader Unit ..................................................................................... 16 2.4. Optional Modules 2.4.1.
4.10.3. Non-redundant configuration of switching hubs ................................... 45 4.10.4. Largest-scale system connection example .......................................... 46 5. PC CONNECTIONS ......................................................................................... 47 6. RETURNING SETTINGS TO THEIR INITIAL FACTORY DEFAULT (D-2008SP ONLY) ............................................................................................ 48 7. FIRMWARE UPDATE PROCEDURE (D-2012C ONLY) ..
11.12. D-971M Line Output Module .......................................................................... 78 11.13. D-971E Line Output Module .......................................................................... 78 11.14. D-971R Line Output Module .......................................................................... 78 11.15. D-2000DA1 Line Output Module .................................................................... 79 11.16. D-972AE Digital Output Module ..................................
1. HANDLING PRECAUTIONS • The power supply cords supplied with the D-2008SP and D-2012C are designed for exclusive use with each equipment. Never use them with other equipment. • Use the unit in locations where the temperature is between +5 to +40 °C (41 to 104 ºF) and the humidity is less than 90 % (no condensation). • The unit is a precision audio component. To prevent failure, do not give the unit strong shocks or vibrations.
2. NOMENCLATURE AND FUNCTIONS 2.1. D-2008SP Digital Mixing Processor Unit The D-2008SP Digital Mixing Processor Unit is designed to have up to 32 audio inputs and outputs in total. A built-in multiple signal processing functions permit the unit to be used as both a mixer and a signal processor. Its audio input/output and control ports can accept plug-in modules, making the unit have a maximum of 32 inputs or 32 outputs and up to 2 control modules.
1. Power switch [POWER ON/OFF] Power is switched on and off with each depression of this switch. 2. Power lamp Lights when the power switch is set to ON. 3. Monitor number Number of channel to be monitored using headphones. 4. Level indicators [PEAK, +12 dB, 0 dB, –40 dB] Indicate the signal level of each individual channel. Indicate the PFL (pre-fader level) value for the input channel, and the AFL (after-fader level) value for the output channel.
25. WORD CLOCK CobraNet indicator (Green) Lights when the master of the internal word clock gets synchronization from CobraNet. 26. WORD CLOCK EXTERNAL indicator (Green) Lights when the master of the internal word clock gets synchronization from the external word clock generator connected to the rear panel's word clock input. • SYSTEM ERROR and SYSTEM RUN indicators vs.
34. MAC address This is the address* used by the unit. Since the relationship of the unit's location to its MAC address is established when setting the network attributes, keep track of this relationship for later use. * The inherent address assigned to each network component, expressed in 12-digit hexadecimal notation. 35. Word clock termination switch Terminates the word clock connection at 75 Ω. To terminate the word clock connection at this unit, shift the switch to the "ON" position.
2.2. D-2012C Remote Console Unit The D-2012C is designed to be used with the D-2008SP Digital Mixing Processor. The D-2012C can be LANconnected to the D-2008SP Processor to allow remote operation of input and output channel volume adjustment, signal level monitoring, contact control and preset memory recall, etc. The D-2012C is equipped with line inputs and audio monitor bus terminal.
• A-Section 2 3 4 1 • B-Section 5 6 1. Power switch Power is switched on and off with each depression of this switch. 4. Key lock indicator Lights red when the operation keys or knobs are locked. 2. Power indicator Lights when the power is switched on. 5. Write-in space Write the name of the function assigned to the key, etc. in these spaces. 3. LAN connection indicator Displays the connection status of the D-2008SP to be controlled.
• C-Section 7 8 9 10 11 12 7. Level indicators [PEAK, +12 dB, 0 dB, –40 dB] Indicate signal levels for each channel. Pre-fader value is indicated for input channels and postfader value for output channels. Adjust the sound volume so that the Peak indicator does not continuously remain lit. 9. Channel ON/OFF keys Turn on or off the output for each channel. Pressing a key causes it to light and the signal of its corresponding channel to be output.
• D-Section 7 8 9 10 12 Note: Refer to p. 12 for names and functions of parts 7 – 10. 12. Rotary encoders (1 – 8) Adjust the volume of each input or output channel. The volume increases as the encoder is rotated clockwise, and decreases as it is rotated counterclockwise. (The knob rotates endlessly.) The volume indicators around the knob light depending on the rotation of the knob. Use the D-2000 Setting Software to perform settings for the input or output channels for which the volume is adjusted.
• E-Section 13 14 15 13. Line input signal level indicators [SIGNAL, PEAK] Display the signal level set with the Line input volume control (15). The SIGNAL indicator lights when a signal exceeding the reference level of –20 dB is fed to the line input terminal. If a signal at the line input terminals clips, the PEAK indicator lights. 14. Line input terminals Connect stereo equipment of stereo line level of –10 dB* and 10 kΩ to these terminals.
[Connection panel] 19 20 21 19. Functional earth terminal Note: This terminal is not for protective earth. 20. AC Inlet Connect this inlet to the wall AC outlet using the supplied power cord. The socket-outlet shall be installed near the equipment and the plug (disconnecting device) shall be easily accessible. 21. Monitor bus terminal An audio transmission connector for the D2008SP. Connects to the D-2008SP's Monitor bus terminal.
2.3. D-911 VCA Fader Unit The D-911 VCA Fader Unit is designed for use with the D-2008SP. Connecting to the D-984VC VCA Control Module installed in the D-2008SP permits volume adjustment of input and output channels and contact controls of the D-2008SP. For details, refer to the instruction manual enclosed with the D-911. [Front] 2 1 3 4 5 1. Input fader Adjusts the volume of each input equipment (i.e. microphones and CD players).
[Rear] 6 7 6. Remote (activation) output terminals Setting the Remote (activation) switch (3) to the ON position closes the output. 7. VCA control module connection terminals These terminals are used exclusively for the D984VC VCA Control module. Use an RJ45 connector for connection. Note Avoid connecting any other than the D-984VC to these terminals.
2.4. Optional Modules Notes • Make sure that the power is switched OFF before attaching or detaching modules. • To avoid failures due to static electricity, do not touch the parts or terminals on the circuit board of both the unit and module. • Ensure that the module is installed and secured with screws in the correct position. • Cover idle slots with the blank panels attached to the unit as shipped by the factory.
2.4.3. D-922F Microphone/Line Input Module MIC/LINE INPUT MODULE ON NORMAL MIC 5 1 OFF : PHANTOM LIFT : GND LINE +4dB(LINE) -36dB(MIC) -10dB(LINE) -50dB(MIC) 6 2: Hot 1: Ground 6. Input sensitivity switch [PHANTOM, GND LIFT, MIC/LINE] 4-pole switch. Enables phantom power (+15 V; ON/OFF, enabled only when set to the MIC position), ground lift and input sensitivity.
2.4.5. D-2000AD1 Microphone/Line Input Module MIC/LINE INPUT MODULE [–50 / –36 / –10 / +4 dB] 1 9 LIFT 10 LIFT 2 LIFT 3 LIFT model D-2000AD1 4 2 :H 3 :C 1 :E 9. Monaural input terminal [1, 2, 3, 4] (XLR-3-31 or equivalent) Electronically balanced input terminal. 2: Hot (Pin 1: Ground, Pin 2: Hot, Pin 3: Cold) Use XLR-3-12C or equivalent for connection.
2.4.6. D-936R Stereo Input Module STEREO SELECT INPUT MODULE [ –10 dB] 1R 1L 2R 2L 3R 3L 4R 4L Note This module cannot be used as a monitor input. 11 model D-936R 11. Stereo input terminal [1L/1R, 2L/2R, 3L/3R, 4L/4R] Unbalanced, RCA jack stereo input terminals. Either a single stereo input can be selected from the 4 available stereo inputs or all 4 stereo channels can be mixed. Mode setting and stereo selection are performed by a PC using the setting software supplied with the D-2008SP.
2.4.9. D-971M Line Output Module LINE OUTPUT MODULE [+4 dB] 1 15 2 15. Monaural output terminal [1, 2, 3, 4] (XLR-3-32 equivalent) Electronically-balanced output terminal. 1: Ground (Pin 1: Ground, Pin 2: Hot, Pin 3: Cold) Output signal level: +4 dB 3: Cold Use XLR-3-11C or equivalent for connection. 2: Hot 3 4 model D-971M 1 :E 2 :H 3 :C 2.4.10. D-971E Line Output Module LINE OUTPUT MODULE [+4 dB] 16 E C 1 H E C 2 H 16.
2.4.12. D-2000DA1 Line Output Module LINE OUTPUT MODULE [–10/+4 dB] 1 18 ON 19 2 3 ON model D-2000DA1 4 1 :E 2 :H 3 :C 18. Monaural output terminal [1, 2, 3, 4] (XLR-3-32 equivalent) Balanced (electronically-balanced) or unbalanced output, switchable. • Balanced output mode (factory preset) (Pin 1: Ground, Pin 2: Hot, Pin 3: Cold) • Unbalanced output mode (Pin 1: Ground, Pin 2: Hot, Pin 3: No connection but may be connected to Pin 1 Ground) The output level can be set to either +4 dB or –10 dB.
2.4.13. D-972AE Digital Output Module DIGITAL OUTPUT MODULE DIGITAL OUT 1/2 20 AES/EBU 18. AES/EBU digital output terminal [AES/EBU, 1/2, 3/4] (XLR-3-32 or its equivalent) Digital output terminal of AES/EBU format. (Pin 1: Ground, Pin 2: Signal, Pin 3: Signal) Use the XLR-3-11C or equivalent for 3: Signal connection. Note Use the digital audio cable with characteristic impedance of 110 Ω for connection. 1: Ground 2: Signal 3/4 model D-972AE AES/EBU 2.4.14.
2.4.16. D-983 Remote Control Module 1-4 5-8 CTRL IN 1-6 7-12 CONTROL UNITS FOR D-901 ONLY REMOTE CONTROL MODULE CTRL OUT 25 4 5 6 7 8 26 9-12 13-18 13-16 19-24 23. Contact input terminal [CTRL IN, 1-6, 7-12, 13-18, 19-24] CTRL IN Six-circuit RJ45 contact input terminals. Pin No. 1 – 6 7 – 12 13 – 18 Individual contact functions are assigned IN 13 IN 7 IN 1 1 by a PC using the D-2000 Setting IN 14 IN 8 IN 2 2 IN 15 IN 9 IN 3 3 Software supplied with the D-2008SP.
2.4.18. D-2000CB CobraNet Interface Module 29 30 31 30 (a) (b) (c) (d) 29. CobraNet terminals [PRIMARY/SECONDARY] Terminals used for CobraNet connection. Connect with the commercially available CobraNet device via a switching hub. Connect the Primary and Secondary terminals to each single switching hub or two cascade-connected switching hubs. Notes • Be sure to connect both the Primary and Secondary terminals to a switching hub.
3. INSTALLATION 3.1. Inserting the D-2000CB WARNING To prevent a fire or electric shock, never open nor remove the unit case, as there are high voltage components inside the unit. Refer all servicing to qualified service personnel. Be sure to install the D-2000CB first before inserting other modules into the slots. Step 1. Remove the D-2008SP's power plug from an AC wall outlet. WARNING Never do this work with the power cord connected to the AC outlet, as doing so may cause electric shock. Step 2.
Step 4. Remove the D-2000CB's panel. Note: The removed 2 screws are used in step 7. Step 5. Insert the D-2000CB's connector into the D-2008SP's internal connector. CAUTION Terminal pins of the connector are exposed on the solder side of the D-2000CB board. Never touch these terminal pins when inserting the connector to prevent finger injury. Step 6. Secure the D-2000CB to the inside of the D-2008SP with 1 screw. Note Be sure to secure the D-2000CB with the screw.
3.2. Rack Mounting CAUTION (When rack mounting screws are supplied) The supplied rack-mounting screws can be used for the TOA equipment rack only. Do not use them for other racks. When installing the unit in a rack other than that of TOA, be sure to use the screws with a diameter of over 5 mm (0.2") and length of over 12 mm (0.47") to mount the unit. Failure to do so may cause personal injury. (When rack mounting screws are not supplied) Rack mounting screws are not supplied with the unit.
3.2.2. D-2012C D-2012C Notes • To achieve sufficient ventilation, be sure to mount a perforated panel larger than 1U size* above the unit. • Do not position the heat-generating component such as a power amplifier immediately below the D-2012C in the rack. Also, keep such components away from each other so that the ambient temperature around the D2012C should not exceed +40 ºC. Failure to do so may shorten the product life. * 1U size = 44.5 mm or 1.
3.3. When Installing the D-2012C on a Desk Attaching the D-2012AS Console Case to the D-2012C allows the D-2012C to be used on a desk. 3.3.1. Components of the D-2012AS Console Case Machine screw M4 x 10: 4 pieces Side panel L Side panel R Decorative panels Armrest Machine screw M4 x 25 (with washer): 11 pieces Rubber foot: 4 pieces 3.3.2. Attaching the D-2012AS Console Case Step 1. Remove 3 screws on each side of the D-2012C to detach the rack mounting brackets. The removed screws are not used.
Step 3. Attach the side panel L to the left side of the D-2012C and side panel R to its right side with 2 each screws. Step 4. Fit each decorative panel into the holes on the side panels L and R, then secure them with 2 each screws from the side panels inside. Decorative panel* 3 Machine screw M4 x 25 (with washer)* Side panel L* Side panel R* 4 Machine screw M4 x 25 (with washer)* Step 5. Attach the armrest to the D-2012C's front panel with 3 screws.
4. CONNECTION 4.1. Connection Example 1 AMX, Crestron, or other control equipment BGM player (Cassette deck, CD player, MD player, etc.
4.2. Connection Example 2 BGM player (Cassette deck, CD player, MD player, etc.
4.3. Removable Terminal Plug Connection Model Number a l1 l2 AI 0,34-8 TQ 2 (0.08) 0.8 (0.03) 12.5 (0.49) 8 (0.31) AI 0,5-8 WH 2.5 (0.1) 1.1 (0.04) 14 (0.55) l2 l1 8 (0.31) Model Number AI 1,5-8 BK a a1 a2 l1 b 3.4 (0.
4.4. Connecting the Monitor Bus Terminal of the D-2008SP and D-2012C When using the D-2012C's Line input terminal or headphone jack, connect the D-2012C's Monitor bus terminal to the Monitor bus terminal on the D-2008SP. Notes • Set the identical ID number for the D-2008SP and D-2012C to be connected through monitor bus terminals. Use the D-2000 Setting Software to set the ID number.
4.5. Audio Monitor Line Connection When Multiple Units Are Connected Connecting multiple D-2008SP units through monitor input and output terminals allows audio signals other than that of the main unit to be monitored.
4.6. D-2012C's AC Power Cord Connection To prevent the AC power cord from accidentally coming off, secure it with the supplied cable clamp as shown below. D-2012C Connection panel Machine screw M3×6 (accessory) Cable clamp (accessory) Power cord (accessory) Screw hole 4.7. D-911 Connection Connect the D-911 to the D-984VC VCA Control Module installed in the D2008SP.
4.8. D-984VC Specifications The optional VCA Fader Unit D-911 can remotely control the VCA Control Module D-984VC. However, You can make a special unit having the same functions as the D-911 referring to the technical information described here. 4.8.1. Connection cable and pin arrangements of each terminal • For connecting to each terminal, use a CAT5 (Category 5) UTP cable fitted with RJ45 connectors at both ends. Note Use a STP cable in an environment where the cable is susceptible to noises.
[Connections to the output channel VCA terminal] D-2008SP's volume 1 2 3 4 5 6 7 8 0V OUT CH 1 OUT CH 2 OUT CH 3 C (GND) V (+5 V) OUT CH 4 V (+5 V) C (GND) D-984VC [OUT CH 1 – 4] RJ45 Minimum level +5 V 4.8.3. Contact controls (5) – (8) • Preset memory recall function is assigned to the contact input and output pins at the factory. To change this function assignment to give channel ON/OFF or stereo input selection, refer to the separate Setting Software Instructions .
4.9. Ferrite Cable Clamp Attachment (For D-972AE only) To reduce electromagnetic noise, place the supplied ferrite clamp over each digital output cable when making a cable connection to the D-972AE Digital Output Module. Install one ferrite clamp per digital output cable. DIGITAL OUTPUT MODULE DIGITAL OUT 1/2 AES/EBU Loop the cable one turn.
4.10. System Expansion Using CobraNet Connection 4.10.1. CobraNet connection outline The system can be expanded by inserting the D-2000CB CobraNet Interface Module into the D-2008SP and connecting it to other CobraNet equipment. Connect the D-2000CB to other CobraNet equipment via a switching hub. Connect each of CobraNet Primary and Secondary ports of the D-2000CB to the same switching hub or different switching hubs connected in cascade.
[Connection example 1: Redundant configuration of switching hubs] D-2000CB CobraNet PRIMARY 3 SW-HUB 2 SW-HUB 1 CobraNet SECONDARY CobraNet PRIMARY (Operating) SW-HUB CobraNet SECONDARY CobraNet unit A CobraNet unit B CobraNet PRIMARY CobraNet SECONDARY (Operating) SW-HUB 4 SW-HUB 5 SW-HUB 6 As shown in the example above, when the CobraNet unit A is operating via the CobraNet PRIMARY and the CobraNet unit B is operating via the CobraNet SECONDARY, 6 switching hubs are used for communica
4.10.2. Redundant configuration of switching hubs In the connection example below, the CobraNet PRIMARY and SECONDARY terminals of each unit are individually connected to different switching hubs. Even if any one of the switching hubs fails or Main line breaks, the system is kept operating using another Main line, thus preventing system down. Notes • Cycle the entire system's power after connection completion. • Perform spanning tree setting within switching hubs.
4.10.3. Non-redundant configuration of switching hubs In the connection example below, both CobraNet PRIMARY and SECONDARY terminals of each unit are connected to the same switching hub. Notes • Cycle the entire system's power after connection completion. • Contact your TOA dealer for more information on switching hubs.
4.10.4. Largest-scale system connection example D-2008SP: D-2012C: PC: D-911: Up to 4 units (Up to 128 inputs/outputs*) Up to 4 units 1 unit Up to 8 units (The D-984VC VCA control module must be inserted into the D-2008SP.*) * Control module cannot be used in a system of 128 audio input/output channels. The maximum number of audio input/output channels decreases to 96 when 8 D-911 units are connected.
5. PC CONNECTIONS Connect a PC, the D-2008SP, and the D-2012C to a switching hub using LAN straight cables individually.
6. RETURNING SETTINGS TO THEIR INITIAL FACTORY DEFAULT (D-2008SP ONLY) Keys and switch used in operation D-2008SP Step 1. Turn off the power. Step 2. Turn on the power while holding down the Selection keys " " and " ." Release all the keys when the "in" indication appears on the Number display. 2 Power switch Selection keys Number display Flashing Step 3. Press the Set key when the "in" indication begins to flash. All setting items return to their initial factory settings.
7. FIRMWARE UPDATE PROCEDURE (D-2012C ONLY) Only when updating the D-2012C firmware ver. 2.0.0, follow the procedure below using the dedicated "D2012C Firmware Updater Software Program*." * Included in the CD supplied with the D-2008SP firmware version 3.0.0 or later. Note When the D-2012C firmware version is 3.0.0 or later, update can be performed using the Setting software via a LAN. D-2012C firmware version can be checked in the connection setting in the Setting software.
Step 5. Set the PC's Com port the D-2012C is connected to, and click [OK] button. The ComSetting screen closes. Note: Set the "Speed" to 115200. Step 6. Click the [Update] button of the D-2012C Firmware update screen. The firmware update starts being transferred from the PC to the D-2012C. The following screen appears after the update ends.
8. OPERATIONS 8.1. D-2008SP Operation Using the front panel-mounted keys, preset memories can be recalled, and input or output channel to be monitored can be selected. Input or output channel can be monitored through headphones connected to a front panel-mounted headphone jack. Its output sound can be adjusted with a front panel-mounted headphone volume control knob. For the channel with stereo link established, it can be monitored in stereo.
8.1.1. Recalling preset memories Follow the procedure below to recall each parameter setting stored as preset memory* using the D-2000 Setting Software or D-2012C Remote console unit. Note When multiple D-2008SP and D-2012C units are installed in the system, the D-2008SP with ID1 must be included to simultaneously operate other units in the system through the following operation. Step 1. Press the Selection key " " or " " several times to light "PRESET" (Item selection indicator).
8.1.2. Selecting the input or output channel to be monitored D-2008SP's input or output channels in operation can be monitored. Step 1. Press the Selection key " " or " " several times to light "MONITOR" (Item selection indicator). MONITOR Lights Step 2. Press the Selection key " " or " " to select monitor number (1 – 32). The monitor selection indicator of the selected number lights. Note: Idle channel is skipped. Monitor Numbers are assigned in groups of 4 to each module slot as shown below.
8.1.3. Selecting the D-2012C's monitor channels The line input and headphone output of the D-2012C Remote Console connected to the D-2008SP processor's Monitor bus terminal can be monitored. Note Before selecting, connect the D-2008SP's Monitor bus terminal to the D-2012C's Monitor bus terminal and perform console settings using the D-2000 Setting Software. Step 1. Press the Selection key " " or " " several times to light “CONSOLE” (Item selection indicator). CONSOLE Lights Step 2.
8.1.4. Selecting CobraNet's monitor channels When the D-2000CB CobraNet Interface Module has been inserted into the D-2008SP and connected to other CobraNet equipment, CobraNet's input and output channel preprogrammed using the D-2000 Setting Software can be monitored. Step 1. Press the Selection key " " or “ " several times to light "CobraNet" (Item selection indicator). CobraNet Lights Step 2. Press the Selection key " " or " " to select monitor number (1 – 32).
8.1.5. Key lock function ON/OFF Enabling the key lock function disables the following operations made on the D-2008SP's front panel. • Recalling preset memories • Selecting the input or output channel to be monitored • Selecting the D-2012C's monitor channels • Selecting CobraNet's monitor channels D-2008SP Enabling the key lock function disables the left and right key operation. [Setting the key lock function to ON] Hold down the Set key for approximately 5 seconds while the Key Lock indicator is unlit.
8.2. D-2012C Operation 8.2.1. Key-assignable functions The following functions can be assigned to the D-2012C's function keys. The function keys are explained on the following pages using the name of the function assigned to each key (example: Memory key). Note To implement the following functions (except Stereo Input) with the function key operation, the D-2008SP with ID1 must be included in the system. • Memory Recalls the setting status stored in preset memory.
8.2.2. Preset memory recall Each parameter stored as preset memory using the D-2000 Setting Software or the D-2012C can be recalled. [Operation] Pressing the Memory key switches the operation panel settings to the setting status stored under the designated preset memory number. In this event, the depressed key lights. Memory 1 Lights Notes • Even if the preset memory number switches, the fader layer number remains unchanged.
8.2.4. Switching Line Inputs (valid only when the D-936R or D-937SP module is installed) This function switches the line inputs (In 1 – 4) of the D-936R Stereo Input Module or the D-937SP Digital Input Module. [Operation] Pressing the Line Input key selects the designated line (stereo) input. In this event, the depressed key lights. Line Input 4 Lights Note The figure shows an example in which "Line Input (In 4)" has been assigned to Function key 4. 8.2.5.
8.2.6. Fader layer switching There are 12 motorized faders and 8 rotary encoders on the D-2012C's operation panel. Store a combination of their channel assignments as a single fader layer in advance using the D-2000 Setting Software. Since 4 different fader layers can be set, up to 4 channels can be assigned to each motorized fader and rotary encoder. By switching the channel assignment status using the Fader Layer key, up to 80 channels can be operated in monaural per D-2012C Console.
8.2.7. D-2008SP control output ON/OFF (console switch) Enables or disables the contact output of the D-981 or D-983 Remote Control Module installed in the D2008SP Digital Mixing Processor. The contact output terminals assigned to the "Console switch" using the D2000 Setting Software can be operated. Operation differs depending on the setting of the contact output terminal's control method.
8.2.9. Key lock function ON/OFF Setting the Key Lock function to ON allows operation of the following keys to be disabled: the D-2012C's operation panel-mounted function keys (except the Key Lock key), motorized faders, rotary encoders, Monitor Channel Selection keys, and Channel ON/OFF keys.
8.2.10. Monitor channel clear This function clears the selection of all the monitor channels assigned to the monitor bus to which the D2012C in operation is connected. [Operation] If the Monitor Clear key is pressed, the selection of monitor channels is cleared and the depressed key lights. Monitor Clear Lights Note The figure shows an example in which "Monitor clear" has been assigned to Function key 3. 8.2.11.
8.3. D-911 Operation Only the D-2008SP's channels to which the D-984VC module is connected can be controlled. Control keys D-911 Input faders Output volume control knobs 8.3.1. Volume adjustment Volume of the channel assigned to the D-984VC using the D-2000 Setting software can be adjusted using the D-911’s input fader or output volume control knob.
9. BLOCK DIAGRAMS 9.1. D-2008SP Line Output Module (D-971M or D-971E) Microphone/Line Input Module (D-2000AD1) +48 V PAD AD DA +48 V PAD AD DA +48 V PAD AD +48 V PAD AD DA DA Line Output Module (D-2000DA1 or D-971R) Microphone/Line Input Module (D-921F or D-921E) +15 V PAD DA AD DA DA +15 V PAD AD DA Digital Output Module (D-972AE) DIT Microphone/Line Input Module (D-922F or D-922E) +15 V PAD DIT DSP (See the next page.
[DSP part block diagram of D-2008SP] Audio Trim Max. 32 From Slot 1 – 8 Max. 4 LED, GUI METER (PFL) HPF/ LPF PEQ COMP/ Leveler Fader VCA ON Audio Bus 24 Audio In 1 – (34) Audio Bus 1 Audio Bus 2 Input Matrix Audio Bus 1 – (24) GUI METER (PFL) GR Trim Auto mix ON BUS Delay GUI METER (AFL) Fader VCA GR Trim FBS MONITOR Ext. In Fader ON MONITOR Max. 4 (Stereo) Sub In Mix Slot 5 – 8 MONITOR Ext.
MONITOR BUS HEAD PHONES Audio Out 1 – (32) L R 4-R 1-L 1-R 2-L CobraNet Out 16 CobraNet Out 1 CobraNet Out 2 Audio Out 32 Audio Out 1 Audio Out 2 Output Matrix Fader VCA LED, GUI METER (TGL) GUI METER (AFL) GR Trim ON Filter/ X over/ Polarity Comp Delay To Slot 1-8 Mute Max. 32 MONITOR LED METER (TGL) MONITOR Max. 4 (Stereo) MONITOR CobraNet Out 1 – (16) Fader VCA LED, GUI METER (AFL) GR Trim ON To D-2000CB (A8, B8) Mute Max. 16 MONITOR Max.
9.2.
9.3.
10. LEVEL DIAGRAMS 10.1. Analog Input/Output Microphone/Line Input Module D-921F, D-921E, D-922F, D-922E, or D-2000AD1, or Stereo Input Module D-936R DSP Line Output Module D-971M, D-971E, D-971R, or D-2000DA1 Digital dBu Max. Input (+24) +20 +10 dBu Clipping Level (+20 dB) +20 Peak LED Turns ON (+17 dB) LINE (+4) +10 (0 dB) (+4) D-971M/E, D-2000DA1*1 0 -10 0 LINE (-10) (–10) D-971R, D-2000DA1*2 -20 -30 -20 MIC (-36) *1 When the output level is set to "+4 dB.
11. SPECIFICATIONS 11.1. D-2008SP Digital Mixing Processor Unit Model No.
LAN Control Operating Temperature Finish Dimensions Weight 1 10BASE-T/100BASE-TX circuit (selectable by automatic recognition), RJ45 connector for maintenance use, connection via a switching hub Network Protocol: TCP/IP Connection Cable: Category 5 or higher shielded twisted pair cable for LAN (CAT5-STP or better) Maximum Cable Distance: 100 m or 109.
11.2. D-2012C Remote Console Unit Model No. Power Source Power Consumption Volume Adjustment Line Input Headphone output Monitor Bus LAN Control Operating Temperature Finish Dimensions Weight D-2012C CE D-2012C CE-AU/CN D-2012C KR D-2012C TW 220 – 240 V AC, 220 – 240 V AC, 220 V AC, 100 – 120 V AC, 50/60 Hz 50 Hz 60 Hz 60 Hz 18 W 100 mm (3.
11.3. D-911 VCA Fader Unit Power Supply Connector Input Fader Control Output Volume Control Contact Control Remote Output Remote Switch Finish Dimensions Weight 5 V DC (supplied from the optional D-984VC) RJ45 connector x 8 Input fader (100 mm or 3.94") x 12 Output volume control x 8 Illuminated switch x 8 No-voltage make contact output (contact capacity: 30 V DC, 4 A) Seesaw switch for activating the remote function of the power distributor Panel: Pre-coated steel plate, black (30 % gloss) 482.
11.5. D-921E Microphone/Line Input Module Input A/D Converter Sampling Frequency Frequency Response Dynamic Range Total Harmonic Distortion Finish Dimensions Weight 2 channels, Mic/Line changeable Mic: –50/–36 dB*, 4.
11.7. D-922E Microphone/Line Input Module Input A/D Converter Sampling Frequency Frequency Response Dynamic Range Total Harmonic Distortion Finish Dimensions Weight 2 channels, –50/–36/–10/+4 dB* (Selectable with the DIP switch), 4.7 kΩ, electronically-balanced, 3-pin removable terminal block Phantom power supply (+15 V, can be set with the DIP switch) Ground lift switch (can be set with the DIP switch) 20 bits 48 kHz 20 Hz – 20 kHz, ±1 dB (+4 dB* input) Over 85 dB (IHF-A weighted) (+4 dB* input) Under 0.
11.9. D-936R Stereo Input Module Input A/D Converter Sampling Frequency Frequency Response Dynamic Range Total Harmonic Distortion Finish Dimensions Weight 4 stereo inputs (Selection of 1 stereo or mixing or all 4 stereo inputs) –10 dB*, 10 kΩ, RCA jack 24 bits 48 kHz 20 Hz – 20 kHz, ±1 dB (+4 dB* input) Over 100 dB (IHF-A weighted) Under 0.05 % Panel: Pre-coated steel plate, black (30 % gloss) 35 (w) x 119.5 (h) x 178.4 (d) mm (1.38" x 4.7" x 7.02") 145 g (0.32 lb) * 0 dB = 0.
11.12. D-971M Line Output Module Output D/A Converter Sampling Frequency Frequency Response Dynamic Range Total Harmonic Distortion Finish Dimensions Weight 4 channels, +4 dB*, adaptable load of over 600 Ω, electronically-balanced, XLR-3-32 type 24 bits 48 kHz 20 Hz – 20 kHz, ±1 dB Over 100 dB (IHF-A weighted) Under 0.05 % Panel: Pre-coated steel plate, black (30 % gloss) 35 (w) x 119.5 (h) x 178.4 (d) mm (1.38" x 4.7" x 7.02") 165 g (0.36 lb) * 0 dB = 0.
11.15. D-2000DA1 Line Output Module Output D/A Converter Sampling Frequency Frequency Response Dynamic Range Total Harmonic Distortion Finish Dimensions Weight 4 channels, +4 dB*/–10 dB* (Selectable with the DIP switch), adaptable load of over 600 Ω, electronically-balanced/unbalanced (Selectable with the DIP switch), XLR-3-32 type 24 bits 48 kHz 20 Hz – 20 kHz, ±1 dB Over 104 dB (IHF-A weighted) Under 0.008 % Panel: Pre-coated steel plate, black (30 % gloss) 35 (w) x 119.5 (h) x 178.4 (d) mm (1.38" x 4.
11.18. D-981 Remote Control Module Contact Input Preset Memory Selection Control Volume Channel Stereo Selection Contact Output Finish Dimensions Weight COM + Terminals 1 – 8: Open voltage: 5 V DC, short-circuit: 5 mA, 10-pin removable terminal block Any preset memory can be recalled. Control method: No-voltage make of over 100 ms or no-voltage make single pulse of over 100 ms Volume can be turned UP or DOWN for any input and output channels.
11.19. D-983 Remote Control Module Contact Input Preset Memory Selection Control Volume Control Channel Stereo Selection Contact Output Finish Dimensions Weight COM + Terminals 1 – 24: Open voltage 5 V DC, short-circuit current 5 mA, RJ45 connector x 4 Any preset memory can be recalled. Control method: No-voltage make of over 100 ms or no-voltage make single pulse of over 100 ms Any input/output channel volume can be turned UP or DOWN.
11.20. D-984VC VCA Control Module VCA Control Input Contact Input Preset Memory Selection Control Volume Control Channel Stereo Selection Contact Output Finish Dimensions Weight +5 V, GND, Terminals 1 – 20 (12 Input channels, 8 output channels), RJ45 connector x 4 Control contacts: Volume control of each input/output channel Variable range: –∞ dB to +10 dB COM + Terminals 1 – 8: Open voltage 5 V DC, short-circuit current 5 mA, RJ45 connector x 2 Any preset memory can be recalled.
11.21. D-2000CB CobraNet Interface Module Network I/F Input Output Sampling Frequency Finish Dimensions Weight CobraNet: 100 BASE-TX, PRIMARY/SECONDARY 2 system RJ45 connector, Enables decentralized installation, Audio transmission only Connection cable: Category 5 or higher shielded twisted pair cable for LAN (CAT5-STP or better) To be connected via the specified switching hub Note: This network should be completely independent of the LAN. Number of D-2008SP connection: Max. 4 Switching hub stage: Max.
URL: http://www.toa.