Manual
161
14. SPECIFICATIONS
14.1. Software Specifications
Operating System: Windows XP Service Pack 2 or later, 32/64-bit Windows Vista, 32/64-bit Windows 7
Required Component: .NET Framework 3.5 SP1
Preset Memory: 32 memories
Bus channel: 4 – 24 buses
14.2. Setting Items, Setting Ranges, and Initial Value
14.2.1. Communication settings
Unit Initial IP address
D-2008SP 192.168.14.1
D-2012C
192.168.14.11
14.2.2. Signal processing box
[Gain Settings]
Setting Item Setting Range Initial Value
Input Trim Gain
–
15 to +15 dB, 0.1 dB
steps
0 dB
Input Trim Polarity
Normal, Inverse Normal
Setting Item Setting Range Initial Value
Audio In 1
–
34 Audio Bus 1
–
24: ON, OFF
– – –
CobraNet In 1
–
16 Audio Bus 1
–
24: ON, OFF
– – –
Gain
–
∞
,
–
69
–
0 dB, 1 dB
steps
0 dB
[Input Matrix (Bus Assignment and Crosspoint Gain) Settings]
Setting Item Setting Range Initial Value
Audio Bus 1
–
24 Audio Out 1
–
32 : ON, OFF
– – –
CobraNet Out 1
–
16 : ON, OFF
Ext. In 1
–
4 Audio Out 1
–
32 : ON, OFF
– – –
CobraNet Out 1
–
16 : ON, OFF
CobraNet Bus 1
–
16 Audio Out 1
–
32 : ON, OFF
– – –
Gain
–
∞
,
–
69
–
0 dB, 1 dB
steps
0 dB
[Output Matrix (Bus Assignment and Crosspoint Gain) Settings]