Manual
166
14.2.3. Settings when the CobraNet module is used
Setting Item Setting Range Initial Value
Bundle 0 – 65279 0
Multicast bundle: 1 – 255
Unicast bundle: 256 – 65279
Latency and Bit Length 5.33 ms (20 bits), 2.67 ms (20 bits, 24 bits), 5.33 ms (20 bits)
1.33 ms (20 bits, 24 bits)
Conductor Priority 0 – 128 32
[Filter Settings]
Filter Type Setting Item Setting Range Initial Value
Parametric Equalizer Center frequency
20 Hz to 20 kHz, 1000 Hz
(PEQ)
1/24
octave steps
Gain
–
15 to +15 dB, 0 dB
(Boos
t
/cut) 0.1 dB
steps
Q 0.267
–
69.249 4.318
High-pass Filter Cutoff frequency
20 Hz to 20 kHz, 100 Hz
(HPF) 1/24
octave steps
Slope 6 dB/oct 12 dB/oct
– – –
Q
– – –
0.500
–
2.563 0.500
Low-pass Filter Cutoff frequency
20 Hz
to
20 kHz, 10 kHz
(LPF) 1/24
octave steps
Slope 6 dB/oct 12 dB/oct
– – –
Q
– – –
0.500
–
2.563 0.500
High Shelving
Filter Rolloff frequency
6 kHz to 20 kHz, 6 kHz
1/24
octave steps
Gain
–
15 to +15 dB, 0 dB
(Boos
t
/cut) 0.1 dB
steps
Low Shelving
Filter Rolloff frequency
20 Hz to 500 Hz, 500 Hz
1/24
octave steps
Gain
–
15 to +15 dB, 0 dB
(Boos
t
/cut) 0.1 dB steps
All Pass
Filter
Phase reversal 20 Hz to 20 kHz, 1 kHz
frequency
1/24
octave steps
Q 0.267
–
69.249 0.267
Notch
Filter Center frequency
20 Hz to 20 kHz, 1 kHz
1/24
octave steps
Q 8.651
–
69.249 8.651
Horn Equalizer (Horn EQ)
Gain 0 to +18 dB, 0 dB
0.5 dB steps
Note
The D-2000 Setting Software version 3.0.0 or
earlier allowed the parameters to be set to 0 –
255. Though using Parameters over 128 set
by this software version permits the unit to
operate, it is recommended to use Parameters
128 or less.