14.2.10. Settings when the D-2012C is used
[Fader layer settings]
[Console setting view (Function key, motorized fader, and rotary encoder settings)]
Setting Item Setting Range Initial Value
Recalling Fader Layer Layer 1
–
4 Layer 1
Fader Layer Recalled When Last Layer, Layer 1
–
4 Last Layer
Power is Turned On
Setting Item Setting Range Initial Value
Function key
None, Memory, Memory Store, Line Input,
Memory 1
–
6,
LED Control, Fader Layer, Console Switch
Memory Store
,
(Contact Output), Key Lock, Monitor Clear Key Lock
Motorized Fader None, Audio In, CobraNet In, Audio Bus, Ext. In,
– – –
CobraNet Bus, Audio Out, CobraNet Out
Rotary Encoder None, Audio In, CobraNet In, Audio Bus, Ext. In,
– – –
CobraNet Bus, Audio Out, CobraNet Out
[Console SEL/MONI link settings]
Setting Item Setting Range Initial Value
Enable SEL/MONI Link Enabled, Disabled Disabled
Console ID to link (ID 1 – ID 4) Enabled, Disabled Disabled
14.2.11. Security settings
Setting Item Setting Range Initial Value
Enable User Level Enabled, Disabled Disabled
Create and Delete Unit, Change Unit Off, Low, Mid, High Off
Unit Naming, Memory Setting Off, Low, Mid, High Off
Store to Memories Off, Low, Mid, High Off
Change Safe Setting Off, Low, Mid, High Off
14.2.12. Change Safe setting
Setting Item Setting Range Initial Value
Enable the "Change Safe" function Enabled, Disabled Disabled
Channel Setting None, a, b, c, d None