20.3.2. Auto mixing function
[Gate Settings]
Setting Item Setting Range
Threshold Level –50 to +20 dB (–40 dB
), 1 dB steps
Hysteresis 0 to +10 dB, 1 dB steps
Depth –∞ to 0 dB (–20 dB), 1 dB steps
Hold Time 10
, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s
Attack Time 10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s
Release Time 10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s
ON/OFF ON, OFF
[Ducker Settings]
Setting Item Setting Range
Priority Level 1
–
8 (in order of the priority level from high to low)
Depth
–
∞ to 0 dB (–20 dB
), 1 dB steps
Attack Time 10
, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s
Release Time 10
, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5, 10 s
ON/OFF ON, OFF
[NOM Attenuation Settings]
Setting Item Setting Range
Attenuation Gain
0 log10
NOM – 20 log10 NOM (10
)
ON/OFF ON, OFF
[Level Sense Settings]
Setting Item Setting Range
Attack Time 0.2, 0.5, 0.7, 1.0, 1.5, 2, 3, 5, 7, 10, 20, 50, 70, 100, 120, 150, 200,
250, 300, 500, 700 ms
1, 2, 3, 5 s
Release Time 10, 20, 50, 70, 100, 120, 150, 200, 250, 300, 500, 700 ms,
1, 2, 3, 5 s
20.3.3. Settings when the D-921E or D-921F is used
Setting Item Setting Range
Phantom Power ON, OFF
PAD (Input Sensitivity) –50, –36, –10, +4
dB
[Auto-Mixing Group Settings]
Setting Item Setting Range
Auto-Mixing Group GROUP A, GROUP B, GROUP C, GROUP D