User guide

50
[Q settings]
[OUT1] F ILTER1
Q 0.267
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the Q.
Parameter setting range: 0.267 – 69.249 (96 points)
Pressing an Output channel selector key permits the filter to be
set for that channel. The [OUT 1] indication changes to the
selected channel number indication.
[Center frequency settings]
[OUT1] F ILTER1
FREQ 1 . 00kHz
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the center frequency.
Parameter setting range: 20 Hz – 20 kHz in 1/24 octave steps
Pressing an Output channel selector key permits the filter to be
set for that channel. The [OUT 1] indication changes to the
selected channel number indication.
9.5. Compressor Settings
ON
When any of the following screens is displayed, the compression function for the displayed channel
can be enabled or disabled with the function ON/OFF key. When enabled (ON), the function
ON/OFF Indicator lights.
[Screen display operations]
Filter settings (P. 45)
Delay time settings (next page)
RatioThreshold level Attack time Release time Makeup gain
[OUT1] COMP
THRESH +0dB
[OUT1] COMP
RAT I O 1 : 1
[OUT1] COMP
GA I N + 0 dB
[OUT1] COMP
ATTACK 10 . 0
m
s
[OUT1] COMP
RELEAS E 50 0
m
s
9.5.1. Threshold level settings
[OUT1] COMP
THRESH +0dB
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the threshold level.
Parameter setting range: –20 to +20 dB in 1 dB steps
Pressing an Output channel selector key permits the compressor
threshold level to be set for that channel. The [OUT 1] indication
changes to the selected channel number indication.
The setting screen reverts to the Input/Output Gain Setting
screen when the shift key is pressed.
9.5.2. Ratio settings
[OUT1] COMP
RAT I O 1 : 1
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the ratio.
Parameter setting range: 1:1, 2:1, 3:1, 4:1, 8:1, 12:1, 20:1, INF
():1
Pressing an Output channel selector key permits the
compression ratio to be set for that channel. The [OUT 1]
indication changes to the selected channel number indication.