User guide

51
9.5.3. Attack time settings
[OUT1] COMP
AT TACK 1 0 . 0
m
s
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the attack time.
Parameter setting range: 0.2 ms – 5 s (Refer to p. 87 for more
information.)
Pressing an Output channel selector key permits the compressor
attack time to be set for that channel. The [OUT 1] indication
changes to the selected channel number indication.
9.5.4. Release time settings
[OUT1] COMP
RELEAS E 500
m
s
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the release time.
Parameter setting range: 10 ms – 5 s (Refer to p. 87 for more
information.)
Pressing an Output channel selector key permits the compressor
release time to be set for that channel. The [OUT 1] indication
changes to the selected channel number indication.
9.5.5. Makeup gain settings
[OUT1] COMP
GA I N + 0 dB
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the makeup gain.
Parameter setting range: –INF (–) to +10 dB in 1 dB steps.
Pressing an Output channel selector key permits the
compression makeup gain to be set for that channel. The [OUT 1]
indication changes to the selected channel number indication.
9.6. Delay Time Settings
[OUT1] DELAY
OFF 0 . 0 0 0
m
s
ON
PARAMETER
PUSH-ENTER
CHANGE
Rotate the Setting knob to set the delay time.
Parameter setting range: 0 – 682.6 ms in 0.021 ms steps
Press the function ON/OFF key to enable or disable the delay
function.
Pressing an Output channel selector key permits the delay time
to be set for that channel. The [OUT 1] indication changes to the
selected channel number indication.
The setting screen reverts to the Input/Output Gain Setting
screen when the shift key is pressed.
Compressor settings