User Manual

20
8.5. Power Amplifier Panel Mounting Position
You need to mount the perforated panel (PF-013B, etc.) above and below each power amplifier panel.
However, up to two power amplifier panels may be stacked without the perforated panel between them
provided each amplifier output power is less than 120 W.
Mounting examples
1. Power amplifier panel rated at 120 W or less (PA-1230B)
Equipment rack
Power amplifier panel
Perforated panel
2. Power amplifier panel rated at 240 W or more (PA-2440B and PA-3640B)
Equipment rack
Power amplifier panel
Perforated panel
Rack Supporting Runner for the power amplifier panel
When installing the power amplifier panel PA-1230B, PA-2440B or PA-3640B, be sure to follow the
instructions in the Equipment Rack Installation Manual and attach the optional guide rail YA-706 to the rack.