Connection method d for the DS-029B
In this method, three or more batteries (multiple DS-029B connection) are connected. A single DS-029B unit
contains two batteries: one to supply power to the operation/control section and one to supply power to the
power amplifier panel.
Battery 3
NDC-2460
Battery 1
NDC-2460
Battery 4
NDC-2460
Battery 2
NDC-2460
Third PA-3640B unit
Rear panel
Second PA-3640B unit
Rear panel
First PA-3640B unit
Rear panel
Second
DS-029B
Rear panel
First DS-029B
Rear panel
JP-0410
Rear panel
[Connection Example]
Rated output: 1080 W
Battery composition: Operation/control section 6 Ah, Power amplifier panel 18 Ah
In the above connection example, power is supplied to the first power amplifier panel PA-3640B from Battery
2, to the second power amplifier panel from Battery 3, and to the third power amplifier panel from Battery 4.
The operation/control section receives power mainly from Battery 1.