5. GENERAL BROADCAST AND ATTENUATOR-FREE BROADCAST
DURING POWER FAILURE
5.1. How to Make "Power-Failure" General Broadcast and Attenuator-Free Broadcast
By installing an emergency power supply panel, which is independent of that for emergency broadcast,
general broadcast can be made even during a power failure using the battery. The battery to be installed in
the emergency power supply panel is optional.
Notes
To make power-failure general broadcast or attenuator-free broadcast, the emergency power supply panel
and battery solely intended for this purpose must be installed in the main rack.
The emergency power supply panel and battery, installed for emergency broadcast, cannot be used for
power-failure general broadcast or attenuator-free broadcast.
5.2. Terminals for Power-Failure General Broadcast and Attenuator-Free Broadcast
The JP-0410 is equipped with two control inputs, power-failure control input and attenuator-free control input,
for activating general broadcast during a power failure.
5.2.1. Power-failure control input
Shorting the power failure control input terminal with the grounding terminal supplies power from the
emergency power supply panel for power-failure general/attenuator-free broadcast to equipment, thereby
enabling broadcast. When the power-failure general broadcast gets started, the speaker line is not selected.
To make broadcast, select the speaker line at the main rack or remote control unit.
Ground
Power-failure general broadcast activation contact.
(Procure this switch separately.)
Contact capacity: 30 VDC, over 100 mA
JP-0410 front-mounted
terminal block
Power-failure
control input
Output
JP-0410
EP-0510
Power-failure general broadcast activation contact.
(Procure this switch separately.)
Contact capacity: 30 VDC, over 100 mA
Digital announcer, etc.
(24VDC-operated equipment)
JP-0410 rear-mounted
terminal block
Ground
Attenuator-free
input
Attenuator-free
control input
Start terminal
+
-
Power-failure general broadcast can be made while the switch for activation of power-failure general
broadcast is at make. If the switch for activation of power-failure general broadcast is at break, the power-
failure general broadcast is terminated, putting the system in the standby mode.
5.2.2. Attenuator-free control input
If the attenuator-free control input terminal is shorted with the grounding terminal, attenuator-free broadcast
can be made to the line set by writing even during a power failure. Only the signal connected to the EP-0510's
attenuator-free input is broadcast. In this event, the broadcast is always attenuator-free broadcast (which is
output to R line).
Closing the attenuator-free control input during AC power operation causes the broadcast to take precedence
over other broadcasts.