Owner's manual

38
9.2.2. Connections
Connecting the Monitor Panel to the Integrated Control Panel EP-0510 permits emergency broadcast to be
monitored at the specific volume level regardless of the volume control setting. When the PA microphone
attached to the EP-0510 is used, the monitoring level automatically lowers to prevent feedback.
For ten input circuits, by changing the jumper connector position, individual power amplifier or line output
levels can be selected. (All inputs are set for the power amplifier output level at the factory.)
All of the ten input circuits can be simultaneously switched to the power amplifier output levels of 50 V, 70 V
or 100 V.
12345 678910
Yellow
Orange
Red
Brown
MP-011 top view (case removed)
MP-011 rear view
MP-0510 rear panel
Jumper connector
(Factory-preset position)
Printed circuit board
100 V, 70 V, 50 V position
1 V (line level) position
To each power amplifier
output or line output
MP-011 power supply
These cables are supplied