User guide
4
Φ48
Φ30
37
260
Lock ring
BATTERY
Power
indicater
6. HOW TO INSERT BATTERIES
Note
Minimizethevolumeofthemixeroramplierconnectedto
thereceiverbeforeopeningorclosingthecase.
Step 1. Rotatethelockringinthearrowdirectionshownat
right, then pull the battery case down to open the
battery compartment.
Step 2. Turn off the power switch.
Step 3. Insert two AA batteries noting correct polarity.
Step 4. Replacethebatterycase,andlockthelockring.
The operation section is backlit while the battery case is
open,anditslightgoesoutwhenclosed.
[Recommended time of battery replacement]
Thebatteryindicatorlightsgreenwhenthebatteryisfullycharged,
and turns into orange followed by red as the battery becomes
weaker. Subsequently, the battery indicator starts ashing red,
thensignaltransmissionwillbestoppedsoon.Whentheindicator
lightsred,replacethebatterieswithnewones.
The power indicator also ashes when the battery indicator is
ashingred.
Rough estimate of operating time on alkaline battery use
Batteryindicatorstatus Remainingbatterylife
Litgreen 2.5 – 5.5 hrs
Litorange 1 – 2.5 hrs
Litred 15min–1hr(Batteriesmustbereplaced.)
Flashingred 0−15min(Batterylifeisabouttoend.)
Notes
• Operatingtimevariesdependingontheconditionofusesuch
as ambient temperature.
• Theindicatorashesgreenifthemicrophoneissettoaninvalid
group/channelforwhichnousablefrequencyisassigned.
(Seep.5.)
• Theindicatorashesorangewhenintestmode.(Seep.7.)
7. DIMENSIONAL DIAGRAM
Unit : mm