12. NETWORK FUNCTION
12.1. Function Overview
The S-D7802 TRANTEC Digital wireless receiver can perform mainly status monitoring and controls of the
receiving system in real time with the dedicated system monitoring software installed into a PC by connecting
the receiver's LAN connector and the PC with an Ethernet cable.
The information displayed on the receiver's front panel is sent to the PC, further detailed information can be
monitored, and the level change of the received RF signal and received audio signal level can be checked by
the PC.
Placing the receiver in Remote mode allows various settings to be remotely performed from the PC. Frequency
usage conditions in adjacent area can be monitored in real time with the radio frequency spectrum display by
automatically sweeping within the receiving frequency band.
Employing the TOA Packet audio system based on the TCP/IP protocol, the S-D7802 can send the digital audio
signals to be internally reproduced to the PC as the packet audio signals in real time as well as the information
aboutlevelmeterandsettings.ByselectingaudiosignalsofthereceivertobemonitoredbythePC,audio
signals can be remotely monitored using the PC's sound reproduction function.
Multiple S-D7802 receivers can be connected to a single PC on a LAN using the commercially available network
HUB.
For the details, refer to the S-D7000 Series Monitoring Software instruction manual contained in the supplied
CD.
PC
S-D7802 (1) S-D7802 (2) S-D7802 (3) S-D7802 (4) S-D7802 (5)
Ethernet cable
NetworkHUB
12.2. Remote/Local Mode Setting
When the receiver is connected to the PC, it is possible to select whether the receiver settings are performed by
the receiver itself or the PC. Settings can be made at the receiver in LOCAL mode and from the PC in REMOTE
mode.
Statuses of receivers can be monitored on the PC regardless of Remote or Local mode setting.
12.2.1 Setting procedures
Step 1. Display "1 RX CONTROL" in the Operation menu display
Step 2. Press the Right key to go to RX CONTROL MENU.
Step 3. Select "REMOTE" or "LOCAL" using the Up and Down keys.
Step 4. Press the SET key.
Thesettingisconrmedandanasterisk
" " is displayed before the mode on the
screen.
Note
In Remote mode, any other settings than Local/Remote selection cannot be
performed using the keys on the receiver's front panel. In Local mode, settings
cannot be performed from the PC.
Also,whentheRemoteindicatorisashing,thereceiverisplacedinReceiver
locationconrmationmodefromthePCbywayofnetworkfunction.Forthe
details, refer to the S-D7000 Series Monitoring Software instruction manual
contained in the supplied CD.
S E L E C T R X C T R L
[