Method
3. Select the activation method from the Activation method drop down list. There are three methods available, each with
different activation times:
ͻ Dwell. Adjust the dwell time by moving the Dwell time slider.
ͻ Switch. Adjust the minimum time for a click duration and the minimum time between clicks by moving the respective
slider.
ͻ Blink. Adjust the minimum and maximum duration for a blink by moving the respective slider.
Visual Feedback
4. Select the symbol for visual feedback from the Dwell feedback type drop down list.
5. Select the color of the feedback symbol in the Feedback color drop down list.
6. Specify the dot size and opacity of the feedback symbol by moving the respective slider.
7. Select the Show visible outline around the activated region check box to see a dashed line around the activated
area in all instances of Gaze Interaction selection
8. Select Simulate activation if you want to see how the activation method will appear on the screen. The example is
shown above the Simulate activation button.
7.4 User Profile
7.4.1 Creating a New Profile
Use of different profiles allows you to store multiple peoples calibrations and feedback preferences on one device. Alternatively,
one person might want to store multiple profiles for him/herself if that person wears glasses occasionally or uses multiple means
of accessing the device.
To create a new profile:
1. Open Gaze Interaction Settings, select User Profiles.
2. Enter a new name in the Profile name field.
3. Select an existing profile in the Based on profile drop down list. The new profile will inherit all settings from the se-
lected profile. Note that if no profiles have been created previously, the only one to select is the default profile.
4. Click Create to save the new profile. The new profile is saved directly upon selecting Create.
Tobii Dynavox I-Series+ Users manual v.1.0 - en-US
7 Gaze Interaction Settings
67