Installation Guide
FCC Notice
This device complies with Part 15 of the FCC Rules and with
Industry Canada license-exempt RSS Standards. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in an installation.
If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and
receiver.
- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician
for help.
Changes or modications not expressly approved by Toggled
could avoid the user’s authority to operate the equipment.
This equipment complies with FCC radiation exposure limits
set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance
20cm between the radiator and your body.
1.844.864.4533 support@toggled.com See toggled.com/warranty for details.
11-02013-AA 2020-11-10
Troubleshooting
Symptom Potential Causes Remedy
LED tube installed
backwards
Ensure the lamp is installed with the “AC Input”
marking on the powered end of the xture
No light from LED tube(s)
when powered on.
Fixture wired improperly
or loose connections exist
Installation (Continued)
6. Fold bracket edges to t the width of the existing xture.
For additional help or support, please contact Toggled support:
Phone 1.844.864.4533. Email support@toggled.com
10. Install new UL Type-B Direct-Wire (Singled-Ended) LED tubes.
Circuit breaker trips when
power is turned on
All other issues
Damaged LED tube
• Verify wiring matches instructions
• Check wire-nuts for loose connections
• Verify voltage at lampholder(s), verify 120-277VAC
is supplied to pins on powered end of lamp
Contact Toggled
(1.844.864.4533, support@toggled.com)
Fixture wired improperly • Verify wiring matches instructions
• Check wire-nuts for loose connections
• Verify voltage at lampholder(s), verify 120-277VAC
is supplied to pins on powered end of lamp
Unknown
Contact Toggled (1.844.864.4533,
support@toggled.com)
9. Reinstall original housing covers using the original retaining clips.
7. Attach new brackets to existing xture using (8) included self-tapping screws.
End-brackets should align with the end of the xture. Use one of the 4ft LED lamps as a guide for aligning the center
bracket.
Screws should be installed using a drill/impact driver with a 1/4” hex-drive bit (not included). Screws should drill holes
on their own, but some may nd it easier to mark required hole locations and pre-drill 1/8” holes before installing
screws.
8. Connect lampholder wire harness to incoming AC power source.
IMPORTANT: Use only UL recognized Type-B LED tubes with this retrot kit.
The total wattage of the LED tubes shall not exceed the rated wattage of the target
luminaire.
Align the powered end of the tubes to the powered lampholders in the center of
the xture.
11. Turn on power to the xture at the circuit breaker.
If any of your tubes do not turn on, check the
orientation.
Conrm tube powered end is connected to the
powered lampholder in center of the xture.
Connect black wire to incoming line wire (typically black) and white wire to incoming neutral wire (typically white).
Line Neutral
Note regarding Toggled Direct-Wire (UL Type-B) Lamps:
Toggled logo and “AC INPUT” markings shown for illustration purposes. When lamp is fully seated in
lampholders, the Toggled logo, “AC INPUT” and other markings should face the xture and the point
of the triangular lamp should face the room.