User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 5-55
5.5.5 SET 22 program setting screen
■ The program setting screen is shown below.
SET22
PROG
STEPN
8
SV1
0
TIM1
0
0
00
ST1BK
0
25
25
SET01
INP1
SV8
0
TIM8
0
0
00
ST8BK
0
STRST
1
ENDST
STEPn
Returns to SET22 PROG
RUNP
1
PV value (present value)
SV value (setting value)
Hold MODE key pressed for 2 seconds
Input 1 setting screen
Press the key several times or key once.
Program setting mode
* When C/P 0, the setting SET 22 is not displayed.
Therefore, all screens thereafter up to RUNP do not appear.
Press MODE key.
Number-of-use-step setting
Press MODE key.
Step designation bank setting
Hold MODE key pressed for 2 seconds
* Repetitively displayed up to StEPN
Press MODE key.
Repetition: 1 to StEPN
Step SV setting
Press MODE key.
Step time setting
Repetitive start step setting
Hold MODE key pressed for 2 seconds
Press MODE key.
Step designation bank setting
Step SV setting
Step time setting
Press MODE key.
Press MODE key.
Press MODE key.
Repetitive end step setting
Execution count setting
Press MODE key.
Press MODE key.
* To be continued to the repetitive start step setting