User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 5-56
5.5.6 Explanation of the screen display and operation of a program run
■ Switching the run screen
Switching between “constant value run,” in
which no program is used, and “program run,” in
which a program automatically executes a run, is
performed with “SET 21 C/P.”
This section describes “program run mode.”
The diagram below shows that the display varies
depending on the difference of run modes.
Note The diagram indicates an example of “TTM-204
operation panel display/operation section.” The
operation method for TTM-205, 207 and 209 is
the same as that for TTM-204.
22
PROG
(0
89
89
%0
0
0
30
0
0
29
(0
0
0
00
0
0
30
(1
0
0
00
0
0
30
(2
0
0
00
0
0
30
(3
PROG
STOP
0
22
%0
0
0
00
0
0
30
(1
0
0
00
0
0
30
(2
0
0
00
0
0
30
(3
0
Constant value run mode
PV/SV screen
PV display
PV value
SV display
SV value
MODE key
SET21
C/P=1
SET21
C/P=0
MODE key
Timer 1 monitor
PV display
Timer 1 ON time
SV display
Timer 1 OFF time
MODE key
Timer 2 monitor
PV display
Timer 2 ON time
SV display
Timer 2 OFF time
MODE key
Timer 3 monitor
PV display
Timer 3 ON time
SV display
Timer 3 OFF time
MODE key
Returns to PV/SV screen.
Program run mode
Program run screen
Auxiliary display
Before run: Blank (no
display)
Run in process: Current
step No.
Run end: “E” displayed
TIME blinks (run).
TIME goes off (stop/end).
MODE key
Step SV screen
Auxiliary display
Before run: Blank (no
display)
Run in process: Current
step No.
Run end: “E” displayed
C (no display of analog
time)
Step time monitor
Auxiliary display
Before run: Blank (no
display)
Run in process: Current
step No.
Run end: “E” displayed
TIME blinks (run in
process)
TIME goes off (stop in
process/run end).
Program run/stop screen
Auxiliary display
Before run: Blank (no
display)
Run in process: Current
step No.
Run end: “E” displayed
Timer 1 monitor
Auxiliary display
1. Before run; run in
process; run end
Timer 2 monitor
Auxiliary display
2. Before run; run in
process; run end
Timer 3 monitor
Auxiliary display
3. Before run; run in
process; run end
PV display
PV value: Before run; run in
process; run end
SV display
Before run: PRoG (before run)
Run in process: Remaining
time
Run end: ENd
PV display
Before run: PV value
Run in process: PV value
Run end: PV value
SV display
Before run: ----
Run in process: Step SV value
Run end: Final step SV value
PV display
Before run: ----
Run in process: Step setting time
Run end: 00:00
SV display
Before run: --:--
Run in process: Step
remaining time
Run end: 00:00
PV display
PRoG: Before run; run in
process; run end
SV display
Before run: StoP (before run)
Run in process: RUN
Run end: End (after run)
PV display
Timer 1 ON time: Before run;
run in process; run end
SV display
Timer 1 OFF time: Before run;
run in process; run end
Returns to the program run screen.
* The monitor only for a set timer is displayed.
Monitors unused are skipped.
PV display
Timer 2 ON time: Before run;
run in process; run end
SV display
Timer 2 OFF time: Before run;
run in process; run end
PV display
Timer 3 ON time: Before run;
run in process; run end
SV display
Timer 3 OFF time: Before run;
run in process; run end
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
* The screens for run mode, step SV
value, step time and program run
start/stop are not displayed.
Details of “program run screen” are described in the next page, “Regarding operation and display of a
program run.”
Auxiliary display
section
PV value
display section
Auxiliary display
section
SV value
display section
SV display
section
PV display
section
PV
SV