User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 5-58
■ Regarding the “program run mode” operation list table
“Program run” is categorized into “before run,” “run in process” and “run end” depending on run status,
for which the operable keys vary. “Operation list table” indicates key operations corresponding to the
status.
“In-stop” indicates before a run, “run in process” a run in process and “After-end” a run ended.
The INDEX ① to ⑯ in the diagram corresponds to “operation and display of a program run” in the
previous page.
< Operation list table (1/3) >
INDEX
Screen
Key operation
Behavior
Run status
Type
Operation method
①
Program run
screen
Before run
MODE
Prolonged press of 2 seconds
To the setting mode
Run in process
MODE
Depression
To step SV value display screen
Run end
FU1-5
Depression
Follows the function key setting.
Prolonged press of 2 seconds
No action
Prolonged press of 2 seconds
No action
Depression
No action
Depression
No action
②
Step SV value
screen
Before run
MODE
Prolonged press of 2 seconds
To the setting mode
MODE
Depression
To step time monitor screen
FU1-5
Depression
Follows the function key setting.
Prolonged press of 2 seconds
Run start
Prolonged press of 2 seconds
No action
Depression
No action
Depression
No action
③
Run in process
MODE
Prolonged press of 2 seconds
To the setting mode
MODE
Depression
To step time monitor screen
FU1-5
Depression
Follows the function key setting.
Prolonged press of 2 seconds
No action
Prolonged press of 2 seconds
No action
Depression
Setting: SV value increased
Depression
Setting: SV value decreased
④
Run end
MODE
Prolonged press of 2 seconds
To the setting mode
MODE
Depression
To step time monitor screen
FU1-5
Depression
Follows the function key setting.
Prolonged press of 2 seconds
No action
Prolonged press of 2 seconds
Run stop
*4
Depression
No action
Depression
No action
Note *4: This key operation is ineffective if “start/stop” is set for the FUNC key or DI.