User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 5-64
■ Regarding the time signal output function
A signal of time signal can be output for each step during a program run. Timers 1 to 3 for step time
are usable as is, as a timer independent from those is used for the signal.
Note The function is active only during a run. Timer operation is also halted during In-stop or
After-end.
Note The timer is reset at step switchover and END transition.
Note Timer operation is skipped to make transition with a step time if a time longer than the step time is set.
Example for StEPN 3
Step 1
Step 2
Step 3
Step start
PV
On delay
Off delay
Timer 1
Soak start
On delay
Off delay
Timer 2
Step start
On delay
Off delay
Timer 3
The count of repetition: 1
The count of repetition: 1
The count of repetition: 1
The count of repetition: 1
The count of repetition: 1
The count of repetition: 1
The count of repetition: 2
The count of repetition: 0 (unlimited)
The count of repetition: 3
All three timers (Timers 1 to 3) are usable at each step. The diagram indicates an example of Timer 1
set for step start, Timer 2 for soak start and Timer 3 for step start. To use a timer for each step,
parameters necessary for the timer function are first set in the bank [SET 20 bNK01 to 16]. For
details, see Section 5.4.5 Timer function (P5-31 to 37).
To use On or Off outputs from Timers 1 to 3 as time signals, set the output destination [o*F] in
“connection destination setting table” to either [5 to 16].
(Connection destination setting table)
SEt05
oUt1
to
SEt11
oUt7
Setting content
Initial value
1
o1F
to
o7F
0
Primary output
o1F:0
o2F:2
to
o7F:2
1
Secondary output
2
Event output
3
RUN output
4
RDY output
5
Timer 1 output
6
Timer 1 during-on-delay output
7
Timer 1 during-off-delay output
8
Timer 1 during-[on + off]-delay output
9
Timer 2 output
10
Timer 2 during-on-delay output
11
Timer 2 during-off-delay output
12
Timer 2 during-[on + off]-delay output
13
Timer 3 output
14
Timer 3 during-on-delay output
15
Timer 3 during-off-delay output
16
Timer 3 during-[on + off]-delay output
17
Transmission output (for analog output)
18
Program run end output