User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 5-67
■ Regarding repetitive run
A repetitive run of a designated step can be executed during a program run. Any step (as a whole or
part) of program steps set in SET 22 can be repeated.
The diagram below shows an example of using this function where the steps 2 and 3 of total 4 steps are
repeated 3 times.
STEP1
STEP2
STEP3
STEP2
STEP3
STEP2
STEP3
STEP4
A program
run begins.
Repetitive start step: STEP 2
Repetitive end step: STEP 3
Repeat count: 3 times
A program
run ends.
The following parameters of SET 22 are used for the repetition setting in program setting mode.
SEt22
PROG
Setting content
Initial
value
5
StRSt
Repetitive start step setting
1
Setting value range: 1 to repetitive end step setting [ENdSt]
6
ENdSt
Repetitive end step setting
StEPN
Repetitive start step setting [StRSt StRSt] up to the
number-of-use-step setting or StEPN
* If StEPN is set, the value set for the number-of-use-step setting
is a setting for “repetitive end step setting.”
7
RUNP
Execution count setting
1
Setting value range: RUNP 0 to 9999
RUNP 0: Unlimited count
In the above example, the setting values are: StRSt 2, ENdSt 3 and RUNP 3.
Use the parameters listed below for the program step data setting in program setting mode.
(Setting regarding the program step data)
SEt22
PROG
Setting content
Initial
value
1
StEPN
Number-of-use-step setting
8
Setting value range: n = 1 to 8
2
St*bK
Step* designated bank setting
0
Setting value range: St*BK = 0 to 7
* = 1 to 8
3
SV*
Step SV* value
0
Setting range value: SV* = SLL to SLH
* 1 to 8
* If SLL or SLH are set in a bank, the value of SLL or SLH is set
for each bank.
4
tIM*
Step* time
00:00
Setting value range: TIM* = 00:00 to 99:59
* = 1 to 8
* With 00:00, a run unlimitedly continues.