User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 5-68
■ Regarding switchover of the input types
If input 1 type [INP 1] is set in a bank, an operation of switching the input type can be executed during
a program run by using the “step* designated bank setting [St*bK] ” function.
Note Note that the input type must be selected from the same group as listed below. Input types from
different groups should not be mixed. Otherwise, switching the decimal point malfunctions.
Input 1 type in Group A
Setting
No.
Input type
Connection
Measurement/
setting range
Designation
resolution
Group A
0
K thermocouple
TC
-200.0 to +1372.0
1C/0.1C
Input type: thermocouple
Decimal point: 0 or 0.0
1
J thermocouple
TC
-200.0 to +1200.0
1C/0.1C
2
T thermocouple
TC
-200.0 to +400.0
1C/0.1C
3
E thermocouple
TC
-200.0 to +1000.0
1C/0.1C
7
N thermocouple
TC
-200.0 to +1300.0
1C/0.1C
8
U thermocouple
TC
-200.0 to +400.0
1C/0.1C
9
L thermocouple
TC
-200.0 to +900.0
1C/0.1C
12
PL II thermocouple
TC
0.0 to +1390.0
1C/0.1C
Input 1 type in Group B
Setting
No.
Input type
Connection
Measurement/
setting range
Designation
resolution
Group B
4
R thermocouple
TC
-50 to +1768
1C
Input type: Thermocouple
Decimal point: 0
5
S thermocouple
TC
-50 to +1768
1C
6
B thermocouple
TC
0 to +1800
1C
10
WRe5-26 thermocouple
TC
0 to +2300
1C
11
PR40-20 thermocouple
TC
0 to +1880
1C
Input 1 type in Group C
Setting
No.
Input type
Connection
Measurement/
setting range
Designation
resolution
Group C
13
Pt100
RTD
-200.0 to +850.0
1C/0.1C
Input type: Resistance
temperature detector
Decimal point: 0 or 0.0
14
JPt100
RTD
-200.0 to +510.0
1C/0.1C
Input 1 type in Group D
Setting
No.
Input type
Connection
Measurement/
setting range
Designation
resolution
Group D
15
0 - 10 mVDC
TC
-19999 to +29999
Display resolution to
be 2000 or less
Random
change of
decimal point
position
allowed
Input type: Resistance
temperature detector
Decimal point: 0 or 0.0
0.00 or 0.000
or 0.0000
16
0 - 1 VDC
I/V
17
0 - 5 VDC
I/V
18
1 - 5 VDC
I/V
19
0 - 10 VDC
I/V
20
4 - 20 mADC
I/V
* The decimal point setting for each bank can vary in a same group.