User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 5-69
■ The diagram below shows an example of a program run with StEPN 8.
STEP1 STEP2 STEP3
STEP4 STEP5 STEP6 STEP7 STEP8
Operation
Start
Operation
End
PV
Operation Stop
Manipulation
Operation Start
Manipulation
STOP
Operation
38
0025%1
48
0015%1
83
0032%2
96
0020%2
BANK1
RMP
10
P1
4.0
o3F
I
20
D
5
BANK1
RMP
10
o3F
BANK1
RMP
10
o3F
BANK1
RMP
10
o3F
BANK2
RMP
5
o3F
BANK2
RMP
5
BANK1
RMP
10
BANK3
RMP
30
BANK0
RMP
P1
3.0
o3F
I
0
D
0
BANK0
RMP
P1
2.0
I
10
D
2
P1
3.0
I
0
D
0
P1
4.0
I
20
D
5
P1
4.0
I
20
D
5
P1
4.0
I
20
D
5
P1
4.0
I
20
D
5
P1
2.0
I
10
D
2
P1
2.0
I
10
D
2
SV1
50℃
TIM1
00:30
ST1BK
BANK1
SV2
100℃
TIM2
00:40
ST2BK
BANK1
SV3
150℃
TIM3
00:50
ST3BK
BANK1
SV4
200℃
TIM4
01:00
ST4BK
BANK1
SV5
150℃
TIM5
00:30
ST5BK
BANK2
SV6
100℃
TIM6
00:40
ST6BK
BANK2
SV7
150℃
TIM7
00:50
ST7BK
BANK1
SV8
20℃
TIM8
00:10
ST8BK
BANK3
St*bK
tIM*
SV*
SV
139
0041%3
147
0025%3
181
0049%4
191
0031%4
151
0016%5
158
0022%5
101
0021%6
104
00 32
%6
148
00 39%7
150
00 29%7
28
0004%8
38
0006%8
20
PROG%0
22
END%0
22
PROG%0
o2F o2F
o2F o2F
o2F o2F
o2F o2F
o2F
o2F
BANK3
RMP
P1
3.0
I
0
D
0
o2F
In the process
of ending
Operation
Suspended
In Program Operation
Operation
Suspended
18 18 18 18 18
o3F
18
o3F
18
o3F
18
o3F
18 18
6
o3F
18
6
*** Time Signal Output Setting ***
*(SET14)tMF1=15, (SET14)tSV1=0, (SET14)oNt1=00:15
Step Start
*(SET6)o2F=6
When Bank 2, o2F=Timer 1 on Delay Output. Other banks are Event Output (nofunction)
*(SET7)o3F=18
End Output
*** Program Function Setting ***
*(SET21)C/P=1, (SET21) PGMD=3, (SET21)PoC=0, (SET21)H/MP=2, (SET21)WAIt=5
Program 2 (w/ Power Failure Compensation), 2: Soak Time 2 (Hr./Min.)
*(SET22) StEPN=8, (SET22) StRSt=1, (SET22) ENdSt=8, (SET22)RUNP=1
*** Other Settings ***
*Set to (SET4) Bank=0. Also, "0" is assumed when BANK switchover is ON by DI.
22 22 2
2
2
2 2
bNK01
5
5
30
(SET21)PGMd=3
Setting Operation
Continuation
oUt2
oUt3
bNK02
bNK03
bNK04
bNK05
bNK06
bNK07
bNK08
bNK09
bNK10
bNK11
bNK12
bNK13
bNK14
bNK15
bNK16
Operation Suspended
(SET4)bANK=0
DI(nonActive)
Program Operation
Display Indication
Time Signal Output
Reference
Bank No.
SET20(bNK)
Setting Value
Operation Suspended
(SET4)bANK=0
DI(nonActive)
SET22(PRoG)
Setting Value
Time Signal Output Setting
• (SET14)tMF1=15, (SET14)tSV1=0, (SET14)oNt1=00:15
Step Start
• SET6)o2F=6
When Bank 2, o2F=Timer 1 on Delay Output. Other banks are Event Output (nofunction)
• (SET7)o3F=18
End Output
Program Function Setting
• (SET21)C/P=1, (SET21) PGMD=3, (SET21) PoC=0, (SET21) H/MP=2, (SET21) WAIt=5
Program 2 (w/ Power Failure Compensation), 2: Soak Time 2 (Hr./Min.)
• (SET22) StEPN=8, (SET22) StRSt=1, (SET22) ENdSt=8, (SET22)RUNP=1
Number-of-use-step: 8, repetitive start step: 1, repetitive end step: 8, execution count: 1
Other Settings
• Set to (SET4) Bank=0. Also, "0" is assumed when BANK switchover is ON by DI.