User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 5-70
5.6 Explanation of the bank automatic switching function
■ Regarding the bank automatic switching function
The bank function can be automatically switched for each temperature. Setting control parameters for
each temperature beforehand enables realization of optimization and an accurate control. As
parameters unrelated to control can also be set similarly to the case of the normal bank function,
application for each temperature is possible for such functions as the timer and event functions.
Note Precaution when using this function together with the program run function
When using this function together with “program run,” the setting is ineffective even when the
bank designation is set using SET 22 “St*bK step* designated bank setting.” All banks are used
with priority when using the bank automatic switching function [SET 23 BAF 1]. Note that a
bank cannot be divided into parts for assigning one of them to, for example, a program run.
(Behavior diagram for explaining the bank automatic switching run)
SV
SLL
①
②
③
④
⑤
④
①
③
Threshold B: PM1 = 140, PM2 = PM3 =
PM4 = PM5 = PM6 = PM7 = SLH
8BANK (All Threshold * Setting <PM1 to PM7>)
Zone threshold setting
Refer
The designated bank is automatically switched
according to the bank automatic switching source.
SV
value
PM7≦
<SLH
SLL≦
<PM1
PM1≦
<PM2
PM2≦
<PM3
PM3≦
<PM4
PM4≦
<PM5
PM5≦
<PM6
PM6≦
<PM7
SET 20
setting value
Max. 16 parameters
Max. 8BANK (Zone threshold = 7)
Bank 0
Bank 1
Bank 2
Bank 3
Bank 4
Bank 5
Bank 6
Bank 7
RMP
RMP
10
RMP
10
RMP
10
RMP
10
RMP
5
RMP
5
RMP
10
P1
3.0
P1
4.0
P1
4.0
P1
4.0
P1
4.0
P1
2.0
P1
2.0
P1
4.0
I
0
I
20
I
20
I
20
I
20
I
10
I
10
I
20
D
0
D
5
D
5
D
5
D
5
D
2
D
2
D
5
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PM* setting
value
Bank
auto-switching
source
Bank
No.
SLH
200C
Bank 7
PM7
160C
⑤150C
Bank 7
PM6
140C
Bank 6
PM5
120C
Bank 5
PM4
90C
④100C
Bank 4
PM3
60C
③70C
Bank 3
PM2
40C
Bank 2
PM1
20C
②35C
Bank 1
SLL
0C
①10C
Bank 0
PM1
PM2
PM3
PM4
PM5
PM6
PM7
Bank 6
Bank 5
Bank 4
Bank 3
Bank 2
Bank 1
Bank 0
Bank 7
SLH
Eight banks at most (threshold 7) can be used; the diagram is an example of all banks used. The
bank can automatically be switched for each temperature. The zone threshold* setting < PM 1 to PM
7 > is set in the SV value setting range from SLL to SLH.
The threshold required for automatic switching is set in SET 23 “bank automatic switching function
setting mode.”
For this function, SET 20 “bank function” must be set beforehand.