User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 5-75
■ Setting example of the bank automatic switching function setting mode (2 banks used)
The example shows a threshold for auto switching to be of one point. In this case, Bank 0 and Bank 1
are used.
SV
SLL
①
②
③
④
⑤
④
①
③
Threshold B: PM1 = 140, PM2 = PM3 =
PM4 = PM5 = PM6 = PM7 = SLH
SLH PM7
PM6
PM5
PM4
PM3
PM2
PM1
When two banks are used
(zone threshold: 1 point):
Zone threshold setting
Bank 0
Refer
Bank 0 and Bank 1 are switched
at 140C as a threshold.
SV
value
PM7≦
<SLH
SLL≦
<PM1
PM1≦
<PM2
PM2≦
<PM3
PM3≦
<PM4
PM4≦
<PM5
PM5≦
<PM6
PM6≦
<PM7
SET 20
setting value
Max. 16 parameters
Two banks are used.
Bank 0
→
→
→
→
→
→
Bank 1
RMP
10
RMP
10
P1
3.0
P1
4.0
I
0
I
20
D
0
D
5
•
•
•
•
•
•
PM* setting
value
Bank
auto-switching
source
Bank
No.
SLH
200C
Bank 1
PM7
200C
⑤150C
Bank 1
PM6
200C
Bank 1
PM5
200C
Bank 1
PM4
200C
④100C
Bank 1
PM3
200C
③70C
Bank 1
PM2
200C
Bank 1
PM1
140C
②35C
Bank 0
SLL
0C
①10C
Bank 0
A
B
A
1
B
Bank 1