User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 1-11
1.6 Basic flow of setting
Power-on
The mode changes to either “constant value run mode” or “program run mode” when four seconds are
elapsed after the power is turned-on.
Initial screen
4 sec
* Constant run value mode is established with the SET 21 operating type setting (C/P 0).
In addition, the SET 21 and 22 parameters are not displayed.
* With SET 23 bAF 1, the auto bank switchover function is selectable.
With bAF 0, the SET 23 parameters are not displayed.
Constant value run mode
* All setting item selection screens can move to the
constant value run mode screen.
MODE key for 2 seconds
The screen SET 01 appears when the run mode
screen moves to each setting item selection screen.
Each setting item selection screen
SET 01 - SET 23
* Using the ▲/▼ key, the setting item selection
screens SET 01 to SET 23 are displayed in
sequence.
(In case of no function registered, the
corresponding screen is not displayed.)
(For bank auto-switchover, see page 6-15.)
Blind setting
screen
Parameter setting
screen in each
SET
* Each parameter setting
screen is displayed in
sequence when the MODE
key is pressed on the
parameter setting screen,
which is displayed when the
MODE key is pressed in each
setting item selection screen
(SET**). Holding the MODE
key pressed for at least 2
seconds moves each
parameter setting screen back
to the run mode screen.
Program run mode
* Program run mode is established
with the SET 21 operating type
setting (C/P 0).
* With SET 23 bAF 1,
the auto bank
switchover function
is selectable.
With bAF 0, the
SET 23 parameters
are not displayed.
MODE key for 2 seconds
Each setting item selection
screen SET 01 - SET 23
* Using the ▲/▼ key, the setting item selection
screens SET 01 to SET 23 open in sequence.
(In case of no function registered, the
corresponding screen is not displayed.)
(For program run, see page 6-13.)
(For bank auto-switchover, see page 6-15.)
Blind setting
screen
Parameter setting
screen in each
SET
* All setting item selection screens can move
to the run mode screen.
* Each parameter setting screen
is displayed in sequence when
the MODE key is pressed on the
parameter setting screen, which
is displayed when the MODE
key is pressed in each setting
item selection screen (SET**).
Holding the MODE key pressed
for at least 2 seconds moves
each parameter setting screen
back to the run mode screen.
* A shortcut to SET 22 can be
made if FU* d is set for the
SET 3 function key function
setting.
(For details, see pages 6-12 and
13.)
* The screen moves back to the run mode screen in case of no key operation in each setting item
selection screen or parameter setting screen in each SET for about 2 minutes.
* For how to set the blind setting, see pages 4-27 and 28, the section 4-2-9 “Basic operation.”