User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 6-58
■ CT 2 target connection setting
SEt12
CT
Setting content
Initial value
1
CI2
1
Connected to OUT 1 (settable when D0)
1
2
Connected to OUT 2 (settable when D0)
3
Connected to OUT 3 (settable when an option existent)
4
Connected to OUT 4 (settable when an option existent)
5
Connected to OUT 5 (settable when an option existent)
6
Connected to OUT 6 (settable when an option existent)
7
Connected to OUT 7 (settable when an option existent)
Set the output measured by CT 2.
Note An analog output cannot be set for the target connection.
In case the Even Output is needed, please refer to P6 – 51 Event Function 3 Setting (CT abnormal).
In case of changing the display color due to CT abnormality, please refer to P6 – 66CT Display color During the CT
Abnormality.
Note At-abnormality display color does not change unless the event function 3 setting (CT abnormality) is set.
Note Take care that the product does not properly operate when the subject of control is connected to an output that is set for the CT
abnormality event.
■ CT 2 current value monitor
SEt12
CT
Setting content
Initial value
2
CM2
0.0 to 50.0 (A)
This function is to display the measurement value of CT 2.
■ CT 2 abnormal current value setting
SEt12
CT
Setting content
Initial value
3
Ct2
0.0 to 30.0 (A)
Function turned off at 0.0 (A) setting
0.0
This function is to set the current value for the CT 2 abnormality.
For the target setting value, see section “5.4.7 Current transformer (CT) abnormality function” on pages 5-40 to 44.