User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 6-71
6.11 Priority screen setting
■ Priority screens 1 to 16 setting
SEt19
PRI
Setting content
Initial value
1
PRI01
Parameters for SEt 01 to SEt 17
oFF
2
PRI02
oFF
3
PRI03
oFF
4
PRI04
oFF
5
PRI05
oFF
6
PRI06
oFF
7
PRI07
oFF
8
PRI08
oFF
9
PRI09
oFF
10
PRI10
oFF
11
PRI11
oFF
12
PRI12
oFF
13
PRI13
oFF
14
PRI14
oFF
15
PRI15
oFF
16
PRI16
oFF
Set parameters frequently used or desired to display in the priority screen.
This enables a quick setting or display of the corresponding screen only by a press of the MODE key in the operating mode.
Max. 16 screens can be set.
Set to “OFF” when priority screens are not used.
Note Parameters not allowed with setting in the priority screens are listed below.
Take care that screens for such parameters are not displayed.
(1) All parameters in the initial value setting mode (SET 18)
(2) All parameters in the priority screen design mode (SET 19)
(3) All parameters in the bank setting mode (SET 20)
(4) All parameters of Program Function Setting (SET 21) 3
(5) All parameters of Program Setting (SET 22) 3
(6) All parameters of Bank Auto-Switch Function Setting (SET 23) 3
(7) Some parameters are not selectable, depending on ordered models.