User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 6-72
6.12 Bank function setting
■ Banks 1 to 16 setting
SEt20
bNK
Setting content
Initial value
1
bNK01
Parameters for SEt 01 to SEt 17
cNT
2
bNK02
oFF
3
bNK03
oFF
4
bNK04
oFF
5
bNK05
oFF
6
bNK06
oFF
7
bNK07
oFF
8
bNK08
oFF
9
bNK09
oFF
10
bNK10
oFF
11
bNK11
oFF
12
bNK12
oFF
13
bNK13
oFF
14
bNK14
oFF
15
bNK15
oFF
16
bNK16
oFF
Max. 16 of any parameter setting value can be changed in the banks 0 to 7.
For the no use of the bank, set the setting to “OFF.”
When the bank function is set, the bank Nos. 0 to 7 are displayed in the bank display section.
T T M-2 0 4
SV
P V
Note Parameters with which no bank function is selectable are listed below. Take care that no screen is displayed.
(1) Bank switchover of the control setting mode (SET 04)
(2) All parameters in the initial value setting mode (SET 18)
(3) All parameters in the priority screen design mode (SET 19)
(4) All parameters in the bank setting mode (SET 20)
(5) All parameters of Program Function Setting (SET 21) 3
(6) All parameters of Program Setting (SET 22) 3
(7) All parameters of Bank Auto-Switch Function Setting (SET 23) 3
(8) Some parameters are not selectable, depending on ordered models.
Bank display