User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 6-73
6.13 PROGRAM FUNCTION SETTING
■Operation Type Setting
SEt21
PGF
Setting Contents
Initial
Value
1
C/P
Operation Type Setting 3
0
0
Constant Operation Mode
1
Program Mode
※1 Operation Type Setting (C/P)
The program operation will take place when the Program Mode is set.
The Program Mode executes the program operation by automatically switching the “Bank Function” and
“Program Step Function”.
Setting Range
0: Constant Operation Mode (Program Mode OFF)
1: Program Mode (Program Mode ON)
■Behavior during the Program Mode
STEP1 STEP2 STEP3 STEP4 STEP5 STEP6 STEP7 STEP8
SV1
50℃
TIM1
00:30
ST1BK
BANK1
BANK1
RMP
10
P1
4.0
・
・
・
o2F
I
20
D
5
SV2
100℃
TIM2
00:40
ST2BK
BANK1
BANK1
RMP
10
・
・
・
o2F
SV3
150℃
TIM3
00:50
ST3BK
BANK1
BANK1
RMP
10
・
・
・
o2F
SV4
200℃
TIM4
01:00
ST4BK
BANK1
BANK1
RMP
10
・
・
・
o2F
SV5
150℃
TIM5
00:30
ST5BK
BANK2
BANK2
RMP
5
・
・
・
o2F
TIMER ON
DELAY
SV6
100℃
TIM6
00:40
ST6BK
BANK2
BANK2
RMP
5
・
・
・
SV7
150℃
TIM7
00:50
ST7BK
BANK1
BANK1
RMP
10
・
・
・
o2F
SV8
20℃
TIM8
00:10
ST8BK
BANK3
BANK3
RMP
30
・
・
・
o2F
RUN OUT
BANK0
RMP
P1
3.0
MAX. 16 PARAMETER
・
・
・
o2F
END OUT
I
0
D
0
BANK0
RMP
・
・
・
o2F
END OUT
START
OPERATION
END
OPERATION
END
PV
BANK0
RMP
MAX
16パラメータ
・
・
・
o2F
END OUT
OPERATION
STOP
STOP
OPERATION
STOP OPERATION
P1
2.0
I
10
D
2
P1
3.0
I
0
D
0
P1
3.0
I
0
D
0
P1
4.0
I
20
D
5
P1
4.0
I
20
D
5
P1
4.0
I
20
D
5
P1
4.0
I
20
D
5
P1
2.0
I
10
D
2
P1
2.0
I
10
D
2
SET22
SETTING
VALUE
MAX. 8 STEPS
SET20
SETTING
VALUE
STEP SV SETTING
STEP TIME SETTING
STEP BANK SETTING
o2F
TEMP. CHANGE PATTERN
REFER
1BANK
OPERATION
STOP
OUTPUT EXAMPLE
TIMER ON
DELAY
o2F