User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 3-3
3.2 Terminal arrangement
Notation for terminal arrangement is as follows.
C: Common
NO: Normal open
+, -: There is polarity for wiring.
A, B, b: There is designation for wiring.
CT: Current transformer input (no polarity)
DI: Digital input
RTD: Resistance temperature detector input
TC: Thermocouple input
I: Current input
V: Voltage input (excluding 0 - 10 mV)
* Parameters can be used for changing input types. (Multi-input)
* “NO” and “C” for outputs are for the equipment model with relay contact output. “+” and “-” for
other than the equipment model with relay contact output.
* Terminal block is not provided in case the model selection is not made at the product model.
★ TTM-204
* Outputs 3 and 4 are for common (C) shared
Relay Open collector
① ⑬ ⑦ NO +
Input power supply
② ⑭ ⑧
NO
+
Output 4
- C ③ ⑮ ⑨ C -
Output 1
+ NO ④ ⑯ ⑩ b +
- C ⑤ ⑰ ⑪ B - -
Output 2
+ NO ⑥ ⑱ ⑫ A +
Relay RTD input TC input Analog input
0 - 10 mV input
Output 3
Other than
relay output
A ⑬ A ⑬ A ⑬
RS-485 RS-485 RS-485
B ⑭ B ⑭ B ⑭
⑮ ⑮ ⑮
CT 1 input DI 1 input CT 1 input
⑯ ⑯ ⑯
⑰ ⑰ ⑰
CT 2 input DI 2 input DI 2 input
⑱ ⑱ ⑱
* Only the above can be selected
for the model with CT and DI.
Specifications for communication
and 2 points of CT
Specifications for communication
and 2 points of DI
Specifications for communication,
1 point of CT and 1 point of DI
Main body rear surface terminals
+
+
+
-
-
-