User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 7-27
7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
Setting data
Character
Setting (monitor) value
Initial value
Unit
Setting
value
Blind
Timer function
tMF1
tMF2
tMF3
1: Auto-start
2: Manual start
3: SV start
4: DI 1 start
5: DI 2 start
6: DI 3 start
7: DI 4 start
8: Event 1 start
9: Event 2 start
10: Event 3 start
11: Event 4 start
12: Event 5 start
13: Event 6 start
14: Event 7 start
15: Step start *1
16: Soak start *1
1
None
Unit
H/M1
H/M2
H/M3
1: Hour/minute
2: Minute/second
1
Hour/
minute/
second
Start SV permissible
range
tSV1
tSV2
tSV3
Temperature: 0.0 to 999.9
0 to 999
Analog: 0 to 9999
C
Digit
ON delay timer
oNT1
oNT2
oNT3
0:00 to 99:59
0:00
Hour/
minute/
second
OFF delay timer
oFt1
oFt2
oFt3
0:00 to 99:59
0:00
Hour/
minute/
second
Repeat count
RUN1
RUN2
RUN3
0 - 99 (infinite with 0)
1
Count
Remaining time
monitor
tIA1
tIA2
tIA3
0:00 - 99:59
Start/stop with the ▲/▼ key
0:00
Hour/
minute/
second
*1: Selectable only on Ver3.xx or later.