User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 3-10
★ Event (DI) input
TTM-204
Terminal Nos. ⑮, ⑯, ⑰ and ⑱
TTM-205
Terminal Nos. ○
28
, ○
29
, ○
30
, ○
31
, ○
32
, ○
33
and ○
34
TTM-207
Terminal Nos. ⑲, ⑳, ○
21
, ○
22
, ○
23
and ○
24
TTM-209
Terminal Nos. ○
28
, ○
29
, ○
30
, ○
31
, ○
32
, ○
33
and ○
34
* When CT 1 or CT 2 is
selected, DI 1 or DI 2 are not
selectable.
* When CT 1 is selected, DT 1
is not selectable.
* When CT 1 or CT 2 is
selected, DI 1 or DI 2 is not
selectable.
* When CT 1 is selected, DI 1 is
not selectable.
* When the output 7 is selected,
DI 3 is not selectable.
TTM-204
TTM-207
TTM-205/209
* For TTM-205/209, the common for
DI 3/DI 4 is shared.
* DI input is optional.
* Max. 4 points are selectable (to be designated at order placement).
* The following functions can be executed through the DI (digital) inputs.
The DI inputs are external no-voltage contact signals.
* List of functions due to DI
Close
Active
Bank switchover
Bank switchover
During constant value run
MD
READY
During program run
Start
Stop
MD
MANUAL
Reverse operation
Forward operation
AT stop
AT start
Timer Stop
Timer Stop
Constant value run
Program run
Step feed (during program run) *1
Pause (during program run) *1
Interlock *1
*1: Selectable only for a program run.
Close: Contact signal OFF
Active: Contact signal ON
-
-
-
-
-
-
-
-
+
+
+
+
+
+
+
+
+