User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 3-12
★ Output
Model
Terminal No.
Output 1
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
TTM-204
③ and ④
⑤ and ⑥
⑦ and ⑨
⑧ and ⑨
TTM-205
③ and ④
⑤ and ⑥
⑲ and ○
21
⑳ and ○
21
⑦ and ⑧
⑨ and ⑩
⑪ and ⑫
TTM-207
③ and ④
⑤ and ⑥
⑪ and ⑬
⑫ and ⑬
⑦ and ⑧
○
23
and ○
24
TTM-209
③ and ④
⑤ and ⑥
⑲ and ○
21
⑳ and ○
21
⑦ and ⑧
⑨ and ⑩
⑪ and ⑫
Assignment of outputs
Type of output
Output 1
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
Primary output
(heating)
Secondary output
(cooling)
Transmission
output
Event output
Timer output
End output
: Output assignment possible
: Output assignment not possible
Type of output and specification
* Outputs 1 and 2
Relay contact
250 VAC, 3 A (resistance loads) and 1a contact
Voltage for SSR drive
0 - 12 VDC (load resistance: 600 or greater)
Open collector
24 VDC, 100 mA (load current)
Voltage
0 - 5 VDC, 1 - 5 VDC and 0 - 10 VDC
(resistance loads: 1 k or greater)
0 - 1 VDC and 0 - 10 mVDC (load resistance: 500 k or greater)
Current
4 - 20 mADC (load resistance: 600 or less)
* Outputs 3, 4, 5, 6 and 7
Relay contact
250 VAC, 1 A (resistance loads) and 1a contact
Open collector
24 VDC, 100 mA (load current)
TTM-204
Output 1
Output 2
Outputs 3 and 4
Relay
SSR/current/voltage/
open collector
Relay
SSR/current/voltage/
open collector
* Outputs 3 and 4 are for common shared
Relay
Open collector