User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 4-4
4.2 Basic operation
Flow of each setting item selection screen and each setting mode is described.
4.2.1 Switchover of parameters (flow as a whole)
* The ▲/▼ key is used for switching over setting item selection screens.
* The MODE key is used for switching over screens in each setting mode.
The screen loops back to the setting item selection screen.
* Some mode screens are not displayed, depending on product specifications.
Operating mode
MODE key held pressed
for 2 seconds
Input 1 setting mode
Key function setting
mode
Control setting mode
OUT 1 setting mode
Bank setting mode
MODE key
S04-51
MODE key
MODE key
▲key
▼key
Input 2 setting mode
MODE key
MODE key
MODE key
▲key
▼key
▲key
▼key
▲key
▼key
▲key
▼key
▲key
▼key
▲key
▼key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
Program run function setting
* Setting parameters of SET 21 C/P or after and those of SET 22 are not
displayed if SET 21 C/P 0.
For details, see pages 6-13 and 14.
Bank auto-switchover function setting
* Setting parameters of SET 23 are not displayed if SET 23 bAF 0.
For details, see page 6-15.
* Nos. located in upper left of each parameter screen is identical to the Nos. for items in each parameter screen.
Notation example S20-1: First item in the parameter screen SET 20.