User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 4-9
21. Anti-reset windup
22. Setting of primary
control operation
amount limiter upper
23. Setting of primary
control operation amount
limiter lower limit
24. Setting of primary control
operation amount change
rate limiter ascending
25. Setting of primary control
operation amount change
rate limiter descending
26. Setting of primary
controller soft start
output
27. Setting of primary
controller soft start
time
28. Setting of primary
control operation
amount at fault
29. Setting of primary
control loop anomaly
PV threshold
31. Setting of primary
control loop anomaly PV
threshold
30. Setting of primary
control operation amount
at fault and control
amount threshold
32. Setting of primary
control loop fault time
33. Setting of primary
control OFF point
position selection
34. Setting of primary control
sensitivity
35. Setting of primary control
OFF point position
36. Primary control safeguard
off timer
(0 to 99 minutes)
37. Primary control
safeguard on timer
(0 to 99 minutes)
38. Secondary control
operation amount
39. Setting of secondary
control output gain
40. Setting of secondary
control proportional band
(0.10 to 10.00 times)
41. Setting of secondary control
proportional interval
To S04-32
MODE key
To S04-42
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
Continued to the next page