User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 4-10
42. Setting of secondary
control operation amount
limiter upper limit
To S04-52
MODE key
43. Setting of secondary
control operation amount
limiter lower limit
44. Setting of secondary
control operation amount
change rate limiter
ascending
45. Setting of secondary
control operation amount
change rate limiter
descending
46. Setting of secondary
control operation amount
at fault
47. Setting of secondary
control loop anomaly PV
threshold
48. Setting of secondary
control loop anomaly MV
threshold
49. Setting of secondary
control loop anomaly PV
change threshold
50. Setting of secondary
control loop fault time
51. Setting of secondary
control sensitivity
52. Setting of secondary
control OFF point
position
53. Secondary control
safeguard off timer
(0 to 99 minutes)
54. Secondary control
safeguard on timer
(0 to 99 minutes)
55. Setting of manual reset
56. Setting of dead band
57. Setting of Ramp time
58. Setting of valve motor
stroke time
59. Setting of valve motor
drive dead band
60. Initial open ratio after AT
completion
To SET 04, item 0
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key
MODE key