User Manual
Table Of Contents
- TTM-200シリーズユーザーズマニュアル 英語 48-7009-D.pdfから挿入したしおり
- TOP
- Contents
- 2. Installation
- 3. Wiring
- 4. Basic operation
- 5. Operating the equipment
- 5.1 Precautions on operating the equipment
- 5.2 Operating monitor display
- 5.3 How to set run settings
- 5.4 How to set each function and description of function
- 5.5 Explanation of the program run function
- 5.5.1 Operation flow of the program run
- 5.5.2 SET 21 program function setting
- 5.5.3 SET 21 program function setting screen
- 5.5.4 SET 22 program setting
- 5.5.5 SET 22 program setting screen
- 5.5.6 Explanation of the screen display and operation of a program run
- 5.5.7 Complementary explanation of the program run
- 5.6 Explanation of the bank automatic switching function
- 6. Explanation on parameters
- 6.1 Input 1 type setting
- 6.2 Remote SV input type setting
- 6.3 Function key function setting
- 6.4 Control function setting
- 6.5 Output (from OUT 1 to OUT 7) type setting
- 6.6 Current transformer (CT) setting
- 6.7 DI setting
- 6.8 Timer function setting
- 6.9 Communication function setting
- 6.10 Initial setting
- 6.11 Priority screen setting
- 6.12 Bank function setting
- 6.13 PROGRAM FUNCTION SETTING
- 6.14 PROGRAM SETTING
- 6.15 BANK AUTOMATIC SWITCHING FUNCTION SETTING
- 7. Appendix
- 7.1 Product specifications
- 7.2 Accessories
- 7.3 Error (abnormality) display
- 7.4 Troubleshooting
- 7.5 Setting list
- 7.5.1 Run mode
- 7.5.2 Input 1 setting mode (SET 01)
- 7.5.3 Input 2 setting mode (SET 02)
- 7.5.4 Key function setting mode (SET 03)
- 7.5.5 Control setting mode (SET 04) (1/4)
- 7.5.6 OUT 1 and 2 setting modes (SET 05 and 06) (1/3)
- 7.5.7 OUT 3 to 7 setting modes (SET 07, 08, 09, 10 and 11) (1/2)
- 7.5.8 CT setting mode (SET 12)
- 7.5.9 DI setting mode (SET 13)
- 7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
- 7.5.11 Communication setting mode (SET 17)
- 7.5.12 Initial setting mode (SET 18)
- 7.5.13 Priority screen setting mode (SET 19)
- 7.5.14 Bank setting mode (SET 20)
- 7.5.15 Program function setting mode (SET 21)
- 7.5.16 Program setting mode (SET 22)
- 7.5.17 Bank automatic switching function setting mode (SET 23)

48-7009-E 4-21
4.2.4 Setting of key functions
How to set key functions is described.
Constant value run mode screen
PV value (present value)
SV value (target value)
Hold MODE key pressed for 2 seconds.
Input 1 setting screen
Hold MODE key pressed for 2 seconds.
Each set screen
Each setting mode
Press the ▲ key twice.
Press it, however, once for TTM-204.
Key function setting screen
Press MODE key.
S03-1 Function key 1 function setting screen
* The function key functions are set in this screen.
For content of key functions, see the function key function assignment table as shown below.
* The number displayed in the screen is coincident with that listed in the assignment table.
* Use the ▲/▼ key for setting the numbers.
* At factory shipment, “00: no function” is set.
* Use the MODE key to move the screen for the setting screen to set the function keys 2 to 5.
The screens change in sequence each time when the MODE key is pressed.
(Note that only the function key 1 is available for TTM-204.)
Each set screen
Each setting mode
Function key function assignment table
No.
Pressing time setting
No.
Function setting
★☆
★☆
0*
N/A
*0
No function
1*
Pressing time of 1 second
*1
Digit shift
2*
Pressing time of 2 seconds
*2
Control mode/control stop
3*
Pressing time of 3 seconds
*3
AT start/AT stop
4*
Pressing time of 4 seconds
*4
Timer start/reset
5*
Pressing time of 5 seconds
*5
Screen reverse feed
*6
ENT
*7
Bank switchover
*8
AUTO/MANUAL switchover
*9
SV/MV screen switchover
*A
Constant value run/program run switchover
*B
Step feed
*C
Pause
*D
SET 22 call-up function
Example 1: 23 Two-second prolonged pressing makes the key effective, enabling the PID auto-tuning
start/stop key setting.
Example 2: 44 Four-second prolonged pressing makes the key effective, enabling the timer function
start/reset key setting.
* Holding the MODE key pressed for 2 seconds moves each setting screen to the operating mode screen.
* In about 2 minutes, each setting screen (or any setting screen) automatically moves back to the operating
mode screen.
* The function key functions A to D are active only during a program run. They are also settable during a
constant value run.
For program run mode screen:
PV value (present value)
SV value (PRoG)
Hold MODE key pressed for 2 seconds
Setting mode is the same as that for constant
value run mode.
(To input 1 setting screen)