Installation Manual

Electromagnetic Lock Installation Instruction
(Indoor Series)
In-swinging
Frameless
Glass Door
Out-swinging
Specifications
Holding Force Curve & Accessories
Optional Bracket
Regular Installation
With L-bracket for
narrow door frames
With U-bracket for frameless
glass door leaf
With LZ-bracket for
in-swinging door frames
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-AM-EM Ver. G Publish:2007.11.07
4-1
Model Holding Force Current Draw Optional Bracket Sensor Output
EM-150 Series
10001 Series
10010 Series
10060 Series
EM-300 Series
EM-350 Series
10004 Series
420mA@12VDC
210mA@24VDC
500mA@12VDC
250mA@24VDC
500mA@12VDC
250mA@24VDC
500mA@12VDC
250mA@24VDC
500mA@12VDCX2
250mA@24VDCX2
500mA@12VDC
250mA@24VDC
500mA@12VDCX2
250mA@24VDCX2
L-300, EM-10001L bracket for narrow
door frames.
LZ-300, LZ-300N, EM-10001LZ bracket for
in-swinging doors.
EM-300L bracket for narrow door frames.
EM-300LZ bracket for in-swinging doors.
L-500 bracket for narrow door frames.
LZ-500,LZ-500N bracket for in-swinging
doors.
L-500 bracket for narrow door frames.
LZ-500N bracket for in-swinging doors.
L-300, EM-10001L bracket for narrow
door frames.
LZ-300N, EM-10001LZ bracket for
in-swinging doors.
L-350 bracket for narrow door frames.
LZ-350 bracket for in-swinging doors.
600 lbs(272 Kg)
600 lbs (272 Kg)
1200 lbs (545 Kg)
600 lbsX2 (272 KgX2)
800 lbs (363 KgX2)
1200 lbsX2
(545 KgX2)
Please note that the actual accessory pack varies according to the
electromagnetic lock model.
Electromagnet
Mounting Plate
Armature
Plate
Sexnut Bolt
Guide Pins
Rubber Washer
Washer
Armature screw
Door spacer
" L Z " Bracket
UBK Bracket
" L " Bracket
Out-swinging
Out-swinging
Identify the door swinging direction and inspect the door frame header to determine if bracket is required. A L- bracket, LZ-bracket or U-bracket(optional)
may be required for the electromagnet depending on the frame header and swinging direction.
Narrow frame
The holding force of the electromagnetic lock is depending on the voltage of
the power supply. The graph below illustrates the change of the holding force
under different voltage. The holding forces of the electromagnetic lock used
here by the manufacture here "Colinear" force.
Fixing screw
Anti-tamper Cap
Holding force
Voltage (12 VDC)
300 lbs(136 Kg)
10002,10002TD,
10005,10005TD
EM-300M
EM-150M
10005,10005TD
EM-350M
10020,10020TD,
10020BZ
10040,10040TD,
10040BZ

Summary of content (4 pages)